Installation manual
PS10270JENAA01 20/10/2004 39
Space
Electrical power supply
At the installation point, three power sockets should be provided for the main and secondary
cabinets and the programming terminal. Each socket must be capable of carrying the rated
voltage of 230 V at 50 or 60 Hz at a current of 10/16 A and must have a third, grounding
conductor for protection against electrical discharges and shock, and to prevent electromagnetic
interference. The power outlets installed must comply with the standard NF C-15100.
Power points should also be provided for the optional equipment.
Note: Do not use an extension cord between the electrical outlet and the ICS power supply
unit.
Protection against electric shock
For the safety of the installers, the ICS must be connected to a 3-wire power point
connected to the general earth for the building.
Use only three-conductor (male and female) connectors: two phase conductors and
one earthing conductor.
24 cm
42.6 cm
20 cm < d < 30 cm
Mains lead 20 cm
Distribution frame