Installation manual
PS10270JENAA01 20/10/2004 61
Installing the LAN cards
These cards are CLX expansion cards. They can only be fitted in the main cabinet.
The position of the PT2 cards in the main cabinet depends on the VOIP4(E) daughter cards, 
according to the following installation rules:
• if a PT2 + VOIP4(E)-16 card is installed, the following types of card cannot be installed in the 
next slot: LXX (LA8, LN8, LM8, CC1, etc.), LRX (LR4, LI1, etc.), MVD and LD4 + ADPCM or 
ADPCM16, 
LD4N + ADPCM16 (and vice versa)
• if a PT2 + VOIP4(E)-32 card is installed in slot 0 of shelf 0, LD4 + ADPCM or ADPCM16 
LD4N + ADPCM16 and LXX cards cannot be fitted in slots 1 to 5
Note: The installation rules for the bare PT2 card or PT2+VOIP4(E)-8 card are the same as for 
CX1 cards. The installation rules for the PT2+VOIP4(E)-16 card are the same as for 
LD4+2
 ADPCM or LD4/LD4N+1 ADPCM 16 cards. The installation rules for the 
PT2+VOIP4(E)-32 card are the same as for LSX cards.
Installing the LAN cards
The PT2 card fitted with the VOIP4 daughter card is installed in the main cabinet in shelf 0.
Card
Main cabinet - Shelf 0
0 1 2 3 4 5
PT2, PT2+VOIP4(E)-8 YES YES YES YES YES YES
PT2+VOIP4(E)-16 YES
NO
YES
NO
YES
NO
PT2+VOIP4(E)-32 YES YES
NO NO
YES YES