Installation manual
PS10270JENAA01 20/10/2004 87
Wiring an asynchronous serial link
The shielded serial link cable with the reference HG2829A is used to connect asynchronous data
terminals to the CA1 card in V24/V10 mode.
The following tables give a list of the circuits in the V24 junction on the CA1 card.
Connecting a DCE (CA1) to a DTE (PC or VT100 console)
Note: Circuit 107 “Data set ready” (PDP or DSR) is not present on the CA1 card. The straps
are not shown in this table.
Connecting a DTE (CA1) to a DCE (modem or V24 adapter)
Note: Circuit 107 “Data set ready” (PDP or DSR) is not present on the CA1 card. The straps
are not shown in this table.
Circ
t
Designation ETTD
Direction
CA1-
>DTE
Connectors
J2 to J5
CA1 card
CCITT EIA CA1
9-
pin
25-
pin
104 RD RD NDE 2 3 ---> A1 received data
103 ED ST/TD NDR 3 2 <--- A2 transmitted data
108 TDP DTR DTR 4 20 <--- B4 data terminal ready output
106 PAE CTS CTS 8 5 ---> B3 flow control input
102 TS GND SGND 5 7 <--- A5 0 V return for junction output
B1 not wired
B2 not wired
105 DPE RTS RTS 7 4 <--- A4 flow control output
109 DS CD CD 1-6 6-8 ---> A3 data terminal input
RET 5 7 B5 0 V return for V10 junction input
Circ
t
Designation DCE
Direction
CA1->DCE
Connectors
J2 to J5
CA1 card
CCIT
T
EIA CA1
9-
pin
25-
pin
104 RD RD NDE 2 3 <--- A2 received data
103 ED ST/TD NDR 3 2 ---> A1 transmitted data
108 TDP DTR DTR 4 20 ---> A3 data terminal ready output
106 PAE CTS CTS 8 5 <--- A4 flow control input
102 TS GND SGND 5 7 ---> A5 0 V return for junction output
B1 not wired
B2 not wired
105 DPE RTS RTS 7 4 ---> B3 flow control output
109 DS CD CD 1 8 <--- B4 data terminal input
RET 5 7 B5 0 V return for junction input (V10)