Installation manual

88 20/10/2004 PS10270JENAA01
Wiring a synchronous serial link
The shielded serial link cable with the reference HG2830A is used to wire interfaces on the CS1
card.
The following tables give a list of the circuits in the V24 junction on the CS1 card.
Connecting a DCE (CS1) to a DTE
Connecting a DTE (CS1) to a DCE
Circ
t
V24 signal name ETTD
ISO 2110
(25 pins)
Direction
CS1->DTE
J2 / J3
CS1 card
CCITT EIA CS1*
104 RD RD NDE 3 <--- A1 received data
103 ED ST/TD NDR 2 ---> A2 transmitted data
108 TDP DTR DTR 20 <--- B4 data terminal ready output
106 PAE CTS CTS 5 ---> B3 flow control input
102 TS GND SGND 7 ---> A5 0 V return for junction output
115 HRM CR HR 15-17 ---> B6 clock received for received data
113 XTC 24 ---> A6 transmitted clock
B2 not wired
105 DPE RTS RTS 4 <--- A4 flow control output
109 DS CD CD 6-8 <--- A3 data terminal input
RET 7 B5 0 V return for V10 junction input
114 HEM TC HT 15 ---> B1 clock received for transmitted data
Circ
t
V24 signal name DCE
ISO 2110
(25 pins)
Direction
CS1-->DCTE
J2 / J3
CS1 card
CCITT EIA CS1
104 RD RD NDE 3 <--- A2 received data
103 ED ST/TD NDR 2 ---> A1 transmitted data
108 TDP DTR DTR 20 ---> A3 data terminal ready output
106 PAE CTS CTS 5 <--- A4 flow control input
102 TS GND SGND 7 ---> A5 0 V return for junction outputs
115 HRM CR HR 17 <---- A6clock received for received data
113 XTC 24 ---> B1 transmitted clock
B2 not wired
105 DPE RTS RTS 4 ---> B3flow control output
109 DS CD CD 8 <--- B4 data terminal input
RET 7 ---> B5 0V return for junction input (V10)
114 HEM TC HT 15 <---- B6 clock received for transmitted data