Safety data sheet

Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
Item no.: 1344137
Material Safety Data Sheet
Page 6 of 10
8. Exposure Controls and Personal Protection
Control parameters:
Ingredients with limit values that require monitoring at the workplace:
12190-79-3 Lithium Cobalt Oxide
TLV (USA) 0.02 mg/m³
MAK (Germany) 0.1 mg/m³
Other Exposure Guidelines:
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962 (11th Cir., 1992).
Appropriate engineering controls:
Engineering Measures: Showers
Eyewash stations
Ventilation systems
Use adequate general or local exhaust ventilation to keep airborne concentrations below the permissible exposure limits.
Ensure adequate ventilation.
Individual protection measures, such as personal protective equipment:
Eye/Face Protection: Tightly sealed goggles
Body protection: Protective work clothing.
Skin protection: Protective gloves
Material of gloves:
The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from
manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can
not be calculated in advance and has therefore to be checked prior to the application.
Penetration time of glove material:
The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.
Respiratory Protection:
No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced,
ventilation and evacuation may be required.
Hygiene Measures:
Handle in accordance with good industrial hygiene and safety practice.