8. Handling and Storage
Handling
Specific safe handling advice: Never throw out cells in a fire or expose to high temperatures. Do not soak cells in water and
seawater. Do not expose to strong oxdizers. Do not give a strong mechanical shock or throw down. Never disassemble, modify
or deform. Do not connect the positive terminal to the negative terminal with electrically conductive material.
Storage conditions (suitable, to be avoided):
Do not place the battery cell near heating equipment, nor expose to direct sunlight for long periods. Elevated temperatures can
result in shortened battery cell life and degrade performance.
Store in cool place (temperature: -20-45°C, humidity: 45-75%).
Incompatible products: Conductive materials, water, seawater, strong oxidizers and strong acids
Packing material (recommended, not suitable): Insulative and tearproof materials are recommended.
9. Exposure Controls and Personal Protection
Engineering controls:
Investigate engineering techniques to reduce exposures use with adequate ventilation and recommended personal protective
equipment.
Eye/Face protection:
Use good industrial practice to avoid eye contact. Processing of this product releases vapors or fumes which may cause eye
irritation. Where eye contact may be likely wear chemical goggles and have eye flushing equipment available
Skin protection:
Minimize skin contamination by following good industrial hygiene practices. Wearing protective gloves is recommended. Wash
hands and contaminated skin thoroughly after handling.
Respiratory protection:
Avoid breathing dust and processing vapors. When adequate ventilation is not available, wear a NIOSH/MSHA respirator
approved for protection against inorganic dusts.
Special clothing:
Rubber gloves.
10. Physical and Chemical Properties
Physical state: Solid
Form: Geometric solid
Color: Metallic color (without outer PVC cover)
Odor: No odor
pH: Not Applicable
Flash point: Not Applicable
Explosion properties: Not Applicable
Density: Not Applicable
Solubility: Not Soluble