Data Sheet

STATIC ELECTRICAL CHARACTERISTICS (over recommended operating conditions)
Symbol Parameter
Test Conditios Value
Unit
V
I
(V)
V
O
(V)
|I
O
|
(µA)
V
DD
(V)
T
LOW
*25
o
CT
HIGH
*
Min. Max. Min. Typ. Max. Min. Max.
I
L
Quiescent
Current
HCC
Types
0/5 5 0.25 0.01 0.25 7.5
µA
0/10 10 0.5 0.01 0.5 15
0/15 15 1 0.01 1 30
0/20 20 5 0.02 5 150
HCF
Types
0/5 5 1 0.01 1 7.5
0/10 10 2 0.01 2 15
0/15 15 4 0.01 4 30
V
OH
Output High
Voltage
0/5 < 1 5 4.95 4.95 4.95
V
0/10 < 1 10 9.95 9.95 9.95
0/15 < 1 15 14.95 14.95 14.95
V
OL
Output Low
Voltage
5/0 < 1 5 0.05 0.05 0.05
V
10/0 < 1 10 0.05 0.05 0.05
15/0 < 1 15 0.05 0.05 0.05
V
IH
Input High
Voltage
0.5/4.5 < 1 5 3.5 3.5 3.5
V
1/9 < 1 10 7 7 7
1.5/13.5 < 1 15 11 11 11
V
IL
Input Low
Voltage
4.5/0.5 < 1 5 1.5 1.5 1.5
V
9/1 < 1 10 3 3 3
13.5/1.5 < 1 15 4 4 4
I
OH
Output
Drive
Current
HCC
Types
0/5 2.5 5 -2 -1.6 -3.2 -1.15
mA
0/5 4.6 5 -0.64 -0.51 -1 -0.36
0/10 9.5 10 -1.6 -1.3 -2.6 -0.9
0/15 13.5 15 -4.2 -3.4 -6.8 -2.4
HCF
Types
0/5 2.5 5 -1.53 -1.36 -3.2 -1.1
0/5 4.6 5 -0.52 -0.44 -1 -0.36
0/10 9.5 10 -1.3 -1.1 -2.6 -0.9
0/15 13.5 15 -3.6 -3.0 -6.8 -2.4
I
OL
Output
Sink
Current
HCC
Types
0/5 0.4 5 0.64 0.51 1 0.36
mA
0/10 0.5 10 1.6 1.3 2.6 0.9
0/15 1.5 15 4.2 3.4 6.8 2.4
HCF
Types
0/5 0.4 5 0.52 0.44 1 0.36
0/10 0.5 10 1.3 1.1 2.6 0.9
0/15 1.5 15 3.6 3.0 6.8 2.4
I
IH
,I
IL
Input
Leakage
Current
HCC
Types
0/18
Any Input
18 ±0.1 ±10
-5
±0.1 ±1
µA
HCF
Types
0/15 15 ±0.3 ±10
-5
±0.3 ±1
C
I
Input
Capacitance
Any Input 5 7.5
pF
*T
LOW
=-55
o
CforHCC device: -40
o
C for HCF device.
*T
HIGH
=+125
o
CforHCC device: +85
o
C for HCF device.
The Noise Margin for both ”1” and ”0” level is: 1Vmin. with V
DD
= 5V, 2 V min. with V
DD
=10 V, 2.5 V min. withV
DD
=15V
HCC/HCF4000B-4001B-4002B-4025B
5/13