User`s manual
ON
. I 019$
OFF
. I 020$
INSERT DATA - OFF
. I 026$
INSERT DATA - ON
. I 041$
SET INSERT DATA*
. I 021$
ON
. I 033$
OFF
. I 034$
GROUP-44
SYMBOLOGIES: CODABAR COUPLING, ADJACENT REQUIRED
CODABAR COUPLING
ADJACENT REQUIRED
ABC-Codabar and CX-Codabar have certain rules regarding
the Stop Character of first bar code and the stop character of
second bar code while in conjunction, while Codabar-
Coupling is enabled, the data from any two Codabar bar codes
can be coupled into one set of data without any limitations
between the Stop character of first bar code and the Start
character of second bar code. The Start and Stop characters
associated with each bar code will be sent.
The data can be any alphanumerics of FULL ASCII Table (GROUP
53-61)
1. The scanner will beep three times as a reminder that a
setting is not yet complete.
2. If you make a mistake, forget a step, etc., Scan RESET to
start again.
If CODABAR ADJACENT
is enabled, the scanner
will only read two adjacent
Codabar bar codes; a
single bar code will not be
read.
Step 1- Scan SET INSERT DATA.
Step 2- Scan any combination of alphanumeric characters from
FULL ASCII Table.
Step 3- Scan SET INSERT DATA.
NOTES:
NOTES:
1. Both ABC-Codabar and CX-Codabar can be enabled together,
except when Codabar-Coupling is also enabled.
2. If ABC-Codabar, CX-Codabar, and Codabar-Coupling are all
enabled at the same time, the scanner will read only Codabar-
Coupling, that is, ABC-Codabar, CX-Codabar will be considered
coupling formats.
SETTING PROCEDURE - SET INSERT DATA