User`s manual

CORRECT SETTING
WRONG SETTING
EXAMPLE :
1. PROJECT ASSIGNMENTS:
1.1. Beep tone: BEEP LOW -- HIGH.
1.2. Capslock Mode: CAPSLOCK ON.
1.3. Reading Mode: CONTINUOUS AUTO OFF.
2. SETTING PROCEDURE:
2.1. Scan BEEP LOW -- HIGH (GROUP 3).
2.2. Scan CAPSLOCK ON (GROUP 11).
2.3. Scan CONTINUOUS AUTO OFF (GROUP2).
3. All parameters will be converted to alphanumeric characters
and shown on the monitor.
4. Print the results shown on the monitor as bar codes with a bar
code printer. The bar codes should be in the Code 39 symbology.
5. Scan these labels with any of the wands that must be
programmed with the same settings as the first wand. Be sure
to scan from the first row to the second and so on sequentially,
top to bottom.
.A017$
....0604
5A025F04
.
.A017$
....
0604
5A02
5F04
.
4
4
4
4
. (Dot)
.A017$
....06045A02
5F04.
12
4+.(Dot)
. A017$
. . . . 0604
5A025F04.
.A017$
..
..0604
5A02
5F04
.
Wrong Setting: The string “....”
consists of 4 Dots, located at the
beginning of second row; do not
break the “....” into multiple strings.
Wrong Setting: The string lengths of the
second and third row do not match the
length requirements, because rows should
be in length of four digits.
.A017$
....06045
A025F04
.
Wrong Setting because you add
“....” after .A017$:
The .A017$ is a FIXED parameter to
enter setup procedure. It is an unchangeable
parameter. Never add, delete or rearrange
data from the FIRST row.
.A017$....
0604
5A02
5F04.
9 x
7 x
. (Dot)
X
4
4
4+.(Dot)
CLONING MODE