Operating instructions
19
c) Mounting the valve operating mechanism to the radiator
• Manually turn the coupling nut to fasten the valve operat-
ing mechanism to the valve (‘1’ in the figure on the right).
When using ‘Danfoss’ valves mount one of the enclosed
adapters to the valve first. The figures 12a, 12b, and 12c
on the next page show the adapters that have to be used
for each valve. Additional adapters for other valves may
be purchased separately.
• Briefly press the button (2) on the valve operating mecha-
nism once. See the figure on the right.
•‘
A3A3
A3A3
A3’ appears on the valve operating mechanism’s LCD
and the valve is closed.
• The antenna symbol then blinks on the display and
‘
0%0%
0%0%
0%’ is displayed.
• Close the battery compartment again.
Please note:
If you purchased the valve operating mechanism separately and not as part of a set
comprising a heating control and valve operating mechanism, for example, then the
security code must first be transmitted. This is described in detail in section 13 d).
• The valve operating mechanism acknowledges receipt of the first wireless protocol with a
signal tone.
• The antenna symbol
s now permanently displayed.
• This completes the installation and you can now adapt the pre-programmed settings to your
individual needs.
Please note:
Proceed as described above, if you wish to install further valve operating mechanisms.
Afterwards, the number of radiators/valve operating mechanisms must be set on
the heating control (section 13 e) and the security code must be transmitted (section
13 d).
Figure 11