Operating instructions

25
If you are using external NC contacts, connect both
cables (fed through the openings near screw ‘B’) with
the screw terminals ‘KL1’ (position ‘D’ in figure 16).
A LED ‘D1
B Opening for wall mounting (in the figure a screw is
already inserted).
C TA1’ button
D Screw terminals for external NC contacts
(‘normally closed’)
E Battery compartment for 2 AAA/micro batteries.
d) Initial operation of the ‘FHT80TF-2’
Insert 2 size AAA/micro batteries into the battery compartment. Make sure that you observe
the correct polarity (see the illustration in the battery compartment or figure 16).
The current operating mode of the door/window contact sensor is indicated by the blinking
D1’ LED.
Blinks 3 times Internal contact is monitored
Blinks 4 times External contacts are monitored
Blinks 5 times Internal and external contacts are monitored
Afterwards a synchronisation phase takes place (for approx. 1 minute), during
which the signal LED blinks every second
If you purchased the door/window contact sensor separately and not as part of a set,
then it must now be registered to the heating control. Afterwards, the operating
mode can be selected.
TA1
D1
+
+
-
+
-
-
KL1
A
B
C
D
E
Figure 16