a) Setting the decalcification time (‘
CALCCALC
CALCCALC
CALC’)
The valve is completely opened and closed once a week. This prevents deposits from blocking
the valve. You can use the special ‘
CALCCALC
CALCCALC
CALC’ function to change the time at which the
decalcification cycle is carried out.
Press the ‘PROG’ button until ‘
SondSond
SondSond
Sond’ is displayed. Then release the ‘PROG’ button.
Use the scroller to select the special ‘
CALCCALC
CALCCALC
CALC’ function.
Confirm this by pressing the ‘PROG’ button.
0
6
12
18
24
MO DI MI DO FR SA SO
Figure 29
Use the scroller to select the day of the week (arrow up symbol ‘a’ beneath the respective
day of the week).
Confirm the day of the week you have selected by pressing the ‘PROG’ button. The time at
which the decalcification cycle will be carried out now appears in the first line of the LCD.
0
6
12
18
24
MO DI MI DO FR SA SO
Figure 30
Use the scroller to change the time.
Confirm the decalcification time that you have set by pressing the ‘PROG’ button. The