Operating instructions
49
m) Radiator offset (‘
OFFSOFFS
OFFSOFFS
OFFS’)
This setting option is only displayed, if you use more than one valve operating
mechanism.
If several radiators are controlled by one heating control, it may be that these radiators do not
heat up to the same level.
The reason for this is that the flow rates of the valves differ greatly, depending on
varying or poorly dimensioned radiators. This problem may be solved by adjusting
the settings of single radiators so that they give off more (positive offset) or less
(negative offset) heat.
• Press the ‘PROG’ button until ‘
SondSond
SondSond
Sond’ appears in the LCD.
• Use the scroller to select the special ‘
OFFSOFFS
OFFSOFFS
OFFS’ function.
• To confirm your selection, briefly press the ‘PROG’ button.
• Use the scroller to select the valve operating mechanism/radiator you require, and confirm
your selection by pressing the ‘PROG’ button.
• Use the scroller to set the offset, and confirm your setting by pressing the ‘PROG’ button.
The heating control then returns to the normal operating mode.
You may have to repeat this process several times until the heating power has been
optimally distributed.