19. Technical specifications
• Range
- to the valve operating mechanism (free-field): ................... up to 100 m
- to the home radio central unit (free-field): ........................... up to 300 m
• Max. number of actuators per heating control: .......................... 8
• Max. number of door/window contact sensors per heating control: 4
• Radio frequency: ......................................................................... 868 MHz
• Power supply for the heating control: ......................................... 2 x AA batteries
(if possible, use alkaline batteries)
• Battery life: ................................................................................... approx. 1 year
• Temperature range when in operation: ...................................... 6 °C to 30 °C
• Number of switching times: ......................................................... 4 per day
• Two-part security code, up to 10,000 possible codes
• Bi-directional radio transmission with the ‘FHZ1000’
• Data is preserved when batteries are replaced
(when a ‘FHZ1000’ is present the date and time are transmitted from the ‘FHZ1000’ to the
heating control. If necessary, data may still need to be entered manually)
20. Declaration of conformity (DOC)
We, Conrad Electronic, Klaus-Conrad-Straße 1, D-92240 Hirschau (Germany), hereby de-
clare that this product complies with the fundamental requirements and other relevant
regulations of directive 1999/5/EG.