Technical Manual
SRT X-BAND RADAR SYSTEMS
OPERATION
304202P003 2.7 Rev. C
│ │ │ │ │ │ │
│ │ │ │ │ │ └── Software Revision (From A to Z)
│ │ │ │ │ └── Warm Up time (²)
│ │ │ │ └── Txrx Program Software Version (> 80)
│ │ │ └── Inner transceiver temperature (¹)
│ │ └── Magnetron Peak Current (Range 00H ± FFH).
│ └── Main Bang Amplitude (Range 00H ± FFH).
└── Power Level (Range 00H ± FFH).
Notes:
(¹) Transceiver temperature: From -99 to 99 Celsius degree (signed value).
(²) Warm Up time: calculated in seconds, when null becomes TXRX READY.
Value of power level, main bang and magnetron peak current during sector blanking are fro-
zen.
2.4.3.3 TIMERS INFORMATION
$PTIM,c--c,x.x,x,x.x,x.x,x.x,x.x,x.x,x.x,x.x,x.x,a*hh<CR><LF>
│ │ │ │ │ │ │ │ │ │ │ │
│ │ │ │ │ │ │ │ │ │ │ └─ Timers validity: A = valid V = invalid
│ │ │ │ │ │ │ │ │ │ └─ System timer (
4
)
│ │ │ │ │ │ │ │ │ └─ Timer M-Pulse Low Freq.
│ │ │ │ │ │ │ │ └─ Timer S-Pulse Low Freq.
│ │ │ │ │ │ │ └─ Timer S-Pulse Medium Freq.
│ │ │ │ │ │ └─ Timer L-Pulse Low Freq. (
3
)
│ │ │ │ │ └─ Timer M-Pulse Medium Freq.
│ │ │ │ └─ Timer S-Pulse High Freq.
│ │ │ └─ Timer Standby
│ │ └─ Status 3
│ └─── Status 2 (
2
)
└───── Status 1 (¹)
Notes:
Status 1 (¹) : Magnetron Type label
Status 2 (
2
) : Integer value indicating the magnetron end of life, from 0 to 999, > 100 mean
end of life.
Status 3 : Spare
(
3
)Timers : Integer value indicating the operated time. LSB is equal to 1 hour.
(
4
)System : Integer value indicating lifetime of transceiver LSB is equal to 1 hour
2.4.3.4 DIGITAL POT. INFORMATION
$PDPI,xx,xx,xx,xx,xx,xx,xx*hh<CR><LF>