AT-S73, AT-S99 and AT-S102 Version 4.0.1 Management Software for the Converteon™ Media Converter Products Software Release Notes Please read this document before you begin to use the management software. Supported Platforms This release supports these management and media converter line cards: AT-S99 Version 4.0.1 Management Software AT-CV5M02 Management Card AT-S73 Version 4.0.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes This release supports the following enclosures and power supply modules. Enclosures AT-CV5000 Chassis AT-CV1200 Chassis AT-CV1203 Chassis AT-CV1000 Chassis Power Supplies AT-PWR14 Power Supply Module AT-PWR15 Power Supply Module This release includes these software release notes and the files listed here: One AT-S99 Version 4.0.1 management software image file This file is the new management software for the AT-CV5M02 Management Module.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes Product Documentation Refer to the Allied Telesis web site at www.alliedtelesis.com for the latest installation and user guides for the Converteon product line. What’s New in Version 4.0.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes If you plan to add a redundant AT-CV5M02 Management Card to the AT-CV5000 Chassis, do not add it until after you’ve updated all the cards. If there is a redundant AT-CV5M02 Management Card in the chassis, remove it until you’ve completed the upgrade procedure. This procedure requires a terminal or a personal computer with a terminal emulator program that can handle lines of up to 125 characters.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes “Phase 7: Upgrading the AT-S99 Management Software on the AT-CV5M02 Management Card to Version 4.0.1” on page 11 If you encounter a problem, refer to “Troubleshooting the Upgrade Procedure” on page 11. Phase 1: Installing the AT-CV5M02 Management Card If the AT-CV5M02 Management Card is new, install the card with these steps: 1. If the chassis contains the AT-CV5M01 Management Card, remove the card from the chassis.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes 2. In the Module Status and Configuration menu, examine the ‘VER’ column for the version numbers of the management software programs on the AT-CV5M02 Management Card and the AT-CM2 and AT-CM70S Line Cards. Line cards that contain either Version 3.0.0 or 4.0.0 of their respective programs can be updated directly to Version 4.0.1. Line cards that have Version 2.0.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes 2. In the IP Parameters Menu, do one of the following: To assign the card a static IP address configuration, enter the values in the IP address, Subnet mask, and Gateway address fields. The values have to be entered in this format: xxx.xxx.xxx.xxx. To assign the IP address configuration with a DHCP server on your network, select Enable DHCP to activate the DHCP client.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes Here is an example of how the window would look if you needed to update the AT-CV5M02 Management Card and the AT-CM202 and AT-CM70S Line Cards. This example is from Version 3.0.0 of the management software. The window in Versions 4.0.0 and 4.0.1 has more selections but is used in the same manner. TFTP Image Download Configuration TFTP Server IP Address: 149.22.12.45 Management Card: ats99_v401.img AT-CM2x2 Image File Name: ats73_cm2x2_v401.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes Multiple Line Card images by Card Type - Select this option to upgrade the cards by model name. You are prompted for the model name of the line cards to upgrade and whether they are local or remote line cards, or both. The model names are: AT-CM2x2 - Select this option to upgrade these line cards: AT-CM201, AT-CM202, AT-CM202/1, AT-CM202/2, AT-CM212A/1, and AT-CM212B/1. AT-CM2Kx - Select this option to upgrade the AT-CM2K0S Line Card.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes Here is an example of the messages you’ll see during the upgrade process: Local Line Card in Slot 2: ----------------------------------------------IPC Ready between Management and Line Card ----------------------------------------------Downloading Image to Local Line Card...... 100% ----------------------------------------------Transfer New Image to Line Card Elapsed: <2 min.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes Phase 7: Upgrading the AT-S99 Management Software on the AT-CV5M02 Management Card to Version 4.0.1 To update the management software on the management card: 1. From the Main Menu, select Image Download. 2. From the Image Download Menu, select Image Download via TFTP. 3. In the Image Download via TFTP menu, select Management Card Image Download.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes — Verify that you correctly entered the names of the image files in the TFTP Image Download Configuration Menu. The filenames must include the “.img” extension. If the upgrade process stops or freezes while the management card is transferring an image file to a line card or while a line card is writing an image file to flash memory, try performing the following procedure: 1.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes AT-S73, AT-S99 and AT-S102 Version 4.0.1 Management Software Known Issues DHCP client. The DHCP client on the AT-CV5M02 Management Card has the following known issues: — There has to be a valid link on the 10/100Base-TX port on the management card before you can enable the DHCP client.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes Operational Notes Starting in Version 3.0.0 the default operating mode for the AT-CM2 and AT-CM70S Line Cards is OAM Visible. (The default operating mode for the AT-CV Line Cards remains Link Test.) To avoid compatibility issues between the AT-CV5M02 Management Card and the media converter line cards in a chassis, all of the cards should have the same version of their management software programs.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes The Activity LED on the twisted pair port on the AT-CM202-v2 Line Card continues to flash after the port is disabled. (6083) If you install the AT-CM70S Line Card in the AT-CV1200 Chassis, you must set the card’s UART parameter to the UART Local Console Mode. Otherwise, the line card might not function properly. Setting this parameter requires the AT-CV5M02 Management Card.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes Version 1.2.0 AT-S70 Version 1.2.0 introduced the following new features: Redundant CPM (Manual and Automatic CPM Switchover) ATI Proprietary Remote Management with Remote Port Configuration Included Smart MissingLink SFP Information Version 1.1.0 AT-S70 Version 1.1.
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes Contacting Allied Telesis This section provides Allied Telesis contact information for technical support as well as sales or corporate information. Online Support You can request technical support online by accessing the Allied Telesis Knowledge Base: www.alliedtelesis.com/support/kb.aspx. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.