Operation Manual

13
Appendix
Appendix
Appendix
Appendix
Guidance
Guidance
Guidance
Guidance and
and
and
and manufacture
manufacture
manufacture
manufacture
s
s
s
s declaration-electromagnetic
declaration-electromagnetic
declaration-electromagnetic
declaration-electromagnetic emission
emission
emission
emission
for
for
for
for all
all
all
all EQUIPMENT
EQUIPMENT
EQUIPMENT
EQUIPMENT and
and
and
and SYSTEMS
SYSTEMS
SYSTEMS
SYSTEMS
Guidance
Guidance
Guidance
Guidance and
and
and
and manufacture
manufacture
manufacture
manufacture
s
s
s
s declaration
declaration
declaration
declaration
electromagnetic
electromagnetic
electromagnetic
electromagnetic emission
emission
emission
emission
The
CMS50 D Pulse Oximeter
is tended for use in the electromagnetic environment specified below. The
customer of the user of the
CMS50 D Pulse Oximeter
should assure that it is used in such an environment .
Emission
Emission
Emission
Emission test
test
test
test compliance
compliance
compliance
compliance Electromagnetic
Electromagnetic
Electromagnetic
Electromagnetic environment-guidance
environment-guidance
environment-guidance
environment-guidance
RF emissions
CISPR 11
Group 1 The
CMS50 D Pulse Oximeter
uses RF energy only for
their internal function. Therefore, its RF emissions are very
low and are not likely to cause any interference in nearby
electronic equipment.
RF emissions
CISPR 11
Class B The
CMS50 D Pulse Oximeter
is suitable for use in all
establishments ,including domestic establishments and
those directly connected to the public low-voltage power
supply network that supplies buildings used for domestic
purposes.
Harmonic emissions
IEC 61000-3-2
Not applicable
Voltage fluctuations/
flicker emission
IEC 61000-3-3
Not applicable
Guidance
Guidance
Guidance
Guidance and
and
and
and manufacture
manufacture
manufacture
manufacture
s
s
s
s declaration-electromagnetic
declaration-electromagnetic
declaration-electromagnetic
declaration-electromagnetic immunity
immunity
immunity
immunity
for
for
for
for all
all
all
all EQUIPMENT
EQUIPMENT
EQUIPMENT
EQUIPMENT and
and
and
and SYSTEMS
SYSTEMS
SYSTEMS
SYSTEMS
Guidance
Guidance
Guidance
Guidance and
and
and
and manufacture
manufacture
manufacture
manufacture
s
s
s
s declaration-electromagnetic
declaration-electromagnetic
declaration-electromagnetic
declaration-electromagnetic immunity
immunity
immunity
immunity
The
CMS50 D Pulse Oximeter
is intended for use in the electromagnetic environment specified specified below.
The the user of
CMS50 D Pulse Oximeter
should assure that it is used in such an environment .
Immunity
Immunity
Immunity
Immunity test
test
test
test IEC60601
IEC60601
IEC60601
IEC60601 test
test
test
test level
level
level
level Compliance
Compliance
Compliance
Compliance level
level
level
level
Electromagnetic
Electromagnetic
Electromagnetic
Electromagnetic
environment
environment
environment
environment - guidance
guidance
guidance
guidance
Electrostatic
discharge (ESD) IEC
61000-4-2
± 6KV contact
± 8KV air
± 6KV contact
± 8KV air
Floors should be wood, concrete or
ceramic tile. If floor are covered
with synthetic material, the relative
humidity should be at least 30%.
Power frequency
(50Hz) magnetic field
IEC 61000-4-8
3A/m 3A/m Power frequency magnetic fields
should be at levels characteristic of
a typical location in a typical
commercial or hospital
environment