Sensor principle MH-C MH-C2
Electrical data
Measuring range ° 0 ... 360 -
Indep. linearitiy (without misalignment) % of meas. range ±0.3 -
Indep. linearitiy (with allowed misalignment @ 360°) % of meas. range ±0.5 -
Max. hysteresis ° 0.1 -
Resolution bit 12 -
Max. repeatability ° 0.1 -
System propagation delay fast mode kHz (5) -
System propagation delay slow mode kHz 1.66 -
System propagation delay fast mode µs (800) -
System propagation delay slow mode µs 4600 -
Max. temperature coefficient of the output signal ppm/°K 50 -
MTTFd / MTBF years 668/668 -
Power supply voltage VDC 5 (±10%) -
Current consumption without load (typ.) fast mode mA (14) -
Current consumption without load (typ.) slow mode mA 9 -
Min. ohmic load at output kOhm 10 -
Max. capacitive load at output nF 10 -
Reverse polarity protection of power supply yes -
Electrical connection axial Wires (3x) -
Cross section of single wires mm
2
0.25 (AWG24) -
Electrical connection radial Cable 3pole -
Cross section of single wires mm
2
0.25 (AWG24) -
Redundancy feasible yes -
Electrical connection redundant axial Ribbon cable 6pole -
Cross section of single wires redundant mm
2
0.09 (AWG28) -
Electrical connection redundant radial Cable 6pole -
Cross section of single wires redundant mm
2
0.25 (AWG24) -
Mechanical data
Mechanical range ° 360 (continuous) -
Protection class IP68 -
Min. life movements no limitation -
Operating & storage temperature (with wires) °C -40 ... +125 -
Operating & storage temperature (with ribbon cable) °C -40 ... +105 -
Operating & storage temperature (with round cable) °C -40 ... +85 -
IEC 68-2-6 Vibration (Amax = 0.75mm, f = 5 … 2000 Hz) g 50 -
IEC 68-2-27 Shock g 200 -
Standards
EN 55022 classe B, Emission radiated (30... 230 MHz) dB(µV/m) max. 30 -
EN 55022 classe B, Emission radiated (230...1000MHz) dB(µV/m) max. 37 -
EN 61000-4-2, ESD (contact discharge / air discharge) kV ±4 / ±8 -
EN 61000-4-3, Immission HF radiated (80... 1000 MHz) V/m 100 -
EN 61000-4-4, Burst (on all lines) kV ±1 -
EN 61000-4-5, Surge (lines to ground) kV ±1 -
EN 61000-4-6, Immission HF conducted (0.15...80MHz) Vemk 10 -
EN 61000-4-8, Immission magnetic field (50Hz) A/m 300 -
IEC 60393-1 Insulation resistance (500VDC, 1bar, 2s) GOhm 20 -
IEC 60393-1 Dielectric strength (VAC, 50Hz, 1min, 1bar) kV 1 -
Vert-X 13E - 5V / 10...90% Ub
Applications
• Servodrives
• Insettingmachines
• Sewerinspectionrobots
• Medicalapplications
Features
• HighprotectionclassIP68
• Verycompactdimensions
• Non-contactingmeasuring
method
• Verylonglife
• Highaccuracyof
measurement
• Useincrampedinstallation
conditions
• Fullresolutionandaccuracy
at programmed electrical
angle
• Fullredundancypossible