Datasheet
Contelec AG
Portstrasse 38
CH-2503 Biel/Bienne
Phone +41 (0)32 3665600
Telefax +41 (0)32 3665604
sales@contelec.ch
A company of the Siedle-Group
Errors and omissions excepted. Subject to
change without notice. State: 02.02.12
Version MH-C MH-C2
Electrical data
Measuring range ° 0 ... 360 -
Indep. linearity % meas. range ±0.3 -
Max. hysteresis ° 0.1 -
Resolution bit 12 -
Max. repeatability ° 0.1 -
Sample rate fast mode kHz (5) -
Sample rate slow mode kHz 1.66 -
System propagation delay fast mode µs (800) -
System propagation delay slow mode µs 4600 -
Max. temperature coefficient of the output signal ppm/°K 50 -
MTTFd / MTBF years 668 / 668 -
Power supply voltage VDC 5 (±10 %) -
Current consumption without load (typ.) fast mode mA (14) -
Current consumption without load (typ.) slow mode mA 9 -
Min. ohmic load at output kOhm 10 -
Max. capactitive load at output nF 100 -
Reverse polarity protection of power supply yes -
Electrical connection Wires (3x) -
Cross section of single wires mm² 0.25 (AWG24) -
Redundancy feasible yes -
Electrical connection redundant Ribbon cable 6pol -
Cross section of single wires redundant mm² 0.09 (AWG28) -
Mechanical data
Mechanical range ° 360 (continuous) -
Protection class IP54 / IP65 -
Max. starting torque at specified protection class Ncm 0.5 / 3 -
Max. rotating speed rpm 120 -
Min. life movements 50 Mio. -
Max. permitted axial shaft load N 10 -
Max. permitted radial shaft load N 10 -
Operating & storage temperature (with wires) °C -40 ... +125 -
Operating & storage temperature (with ribbon cable) °C -40 ... +105 -
IEC 68-2-6 Vibration (Amax = 0.75mm, f = 5 … 2000 Hz) g 20 -
IEC 68-2-27 Shock g 50 -
Standards
EN 55022 class B, Emission radiated (30... 230 MHz) dB(µV/m) max. 30 -
EN 55022 class B, Emission radiated (230...1000MHz) dB(µV/m) max. 37 -
EN 61000-4-2, ESD (contact discharge / air discharge) kV ±4 / ±8 -
EN 61000-4-3, Immission HF radiated (80... 1000 MHz) V/m 30 -
EN 61000-4-4, Burst (on all lines) kV ±1 -
EN 61000-4-5, Surge (lines to ground) kV ±1 -
EN 61000-4-6, Immission HF conducted (0.15...80MHz) Vemk 10 -
EN 61000-4-8, Immission magnetic field (50Hz) A/m 300 -
IEC 60393-1 Insulation resistance (500VDC, 1bar, 2s) GOhm 20 -
IEC 60393-1 Dielectric strength (VAC, 50Hz, 1min, 1bar) kV 1 -
Vert-X 16 - 5V / 10...90% Ub
Applications
• Servodrives
• Dancerarm
•Operatingtable
Features
• Compactdimensions
• Mountingtabswithmetal
inlets
• Contactlessmeasuring
method
• Longlife
• Highaccuracyof
measurement
• Useincrampedinstallation
conditions
• Fullresolutionandaccuracy
at programmed electrical
angle
• Fullredundancypossible