Product Manual AV6x4 Audio/Video Router, 6x4 January 14, 2003 17630 Davenport Rd, Suite113 Dallas, TX 75252 USA Tel: 972.931.2728 888.972.2728 Fax: 972.931-2765 Web: www.crwww.com www.contemporaryresearch.
Table of Contents Overview............................................................................................................................................. 3 Specifications...................................................................................................................................... 4 Physical .................................................................................................................................................4 Front Panel .......................
Overview Contemporary Research presents the AV6x4, a flexible, controllable matrix switcher for routing six stereo A/V inputs to four stereo A/V outputs. Using the simplified front-panel controls, it's easy to switch VCRs, DVDs CDs, cameras and other sources to TVs, projectors, and plasma displays. Route and input to any combination of outputs, send both audio and video, or switch audio and video separately.
Specifications Physical Size: Weight: Enclosure: Front Panel Mute All A/V: Routing Mode: Routing Control: Rear Panel Power In: RS-232 Connector: Audio Inputs: Audio Outputs: Video Inputs: Video Outputs: 19" [483mm] wide x 1.75" [38mm] height (1RU) x 9.25" [235mm] deep 4.25lbs [1.
Front Panel Programming To Enter a Front Panel Programming Mode 1. Press and hold the Mute A/V button until the red LED light above is lit (indicating Mute On). 2. Press Input 1-6 in the Output A/C section to select Programming Mode 1-6. The Mode and Output A-D LEDs (yellow) will turn off when programming mode is selected. 3. Release Mute A/V button to enter selected front-panel programming mode. 4. The A/C Input and B/D Input LEDs will display the current setting for the mode 5.
Front Panel Programming Quick Reference Mode 1 Function Baud Rate A/C 1 2 3 4 5 6 Parameter 300 600 1200 2400 4800 9600 (default 2 Unit Number 1 2 3 Unit 1 Unit 2 Unit 3 3 Input Level 1 2 3 4 5 6 Input Input Input Input Input Input 4 Panel Lockout 1 2 3 4 5 6 All functions enabled Output Selects disabled Mode disabled Output Selects, Mode disabled Mute All A/V disabled Output Selects and Mute All A/V 6 Test Mode 1 2 3 4 5 6 B/D Parameter 1 2 3 4 5 6 All Off -9 dB -6 dB -3 dB +3 dB +6 d
RS-232 Control Protocol Overview The AV6x4 full-duplex RS-232 scheme enables a system programmer to control all routing functions as well as monitor 3 groups of unit status. All commands are sent as ASCII strings. No delays between characters or commands are required, as data is interrupt driven and buffered. There are three types of commands and responses—Crosspoint, Input Gain and Front Panel. Crosspoint commands route Input 1-6 audio and video to Outputs 1-4.
RS-232 Commands Crosspoint Commands A Crosspoint command sends inputs to outputs. The command structure is simple: > [Unit] [Crosspoint (X, A, V)] [Input (0-6)] [Output (A-D)] [Input] [Output]… More than one set of Input/Output points can follow the Crosspoint command. You don’t have to include all Input/Output Crosspoints in the string, only the Crosspoints that need to be changed. A carriage return is required at the end of each command and is assumed in all examples.
Audio Gain Commands An Audio Gain command adjusts the attenuation or gain of each Input. > [Unit] [Gain] [Input (1-6)] [Level (1-6)] [Input] [Level]… More than one set of Input/Gain pairs can follow the Gain command. You don’t have to include all Input/Gain pairs in the string, only the ones that need to be changed. A carriage return is required at the end of each command and is assumed in all examples.
Front Panel Commands Front Panel Commands emulate the functions of front-panel operation and programming. > [Unit] [Panel] [Mode] [Output A/C] [Output B/D] [Lockout] All four parameters (Mode, Output A/C, Output B/D, Lockout) must be included in string. A carriage return is required at the end of each command and is assumed in all examples.
Response Strings Typical: [Attention] [Unit#] [data ...data] [cr] [lf] AV6x4status response strings contain ASCII characters similar to those used for the same functions in command strings. An ASCII 'carriage return' and ‘line feed' follow each response string.
RS-232 Cable Connections All drawings show pin numbers relative to a PC COM port or Axcent3 DB-9 RS-232 control port. Pin-outs to other types of control ports may vary. Single Unit RS-232 Wiring – Single Unit RS-232 Control Port 5 GND GND 5 2 RXD TXD 3 3 TXD RXD 2 9-pin D-sub female Multiple RS-232 Units Up to three Contemporary Research 232-series components can be daisy-chained from one RS-232 control port.
Safety Instructions Read before operating equipment. 1. Cleaning - Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 2. Power Sources - Use supplied or equivalent UL/CSA approved low voltage DC plug-in transformer. 3.
Limited Warranty and Disclaimer Contemporary Research Corporation (CR) warrants this product to be free from defects in material and workmanship under normal use for a period of two years from the date of purchase from CR. Should such a defect occur CR will repair or replace, at their option, the defective product at no cost for parts or labor. This warranty extends to product purchased directly from CR or an Authorized CR Dealer.