Owner's manual

Contemporary Research 6 ICC1-232 Manual
Installation
Setting Device Number and Parameters
In the next step, you’ll need to set up the device number and operation parameters for the ICC1-232. Turn the
enclosure so that the DIP switches are on the bottom as shown.
1. Make sure S2 Switch 6 is OFF (unit in Device mode).
2. Set the Device number by turning on the switches that add up to the desired device number. For
example, for Device #259, turn on S1 switches 1 and 2 (3), S2 switch 1 (256)
Zone Switch Settings
To define the controller’s Zone #, use the following pattern of switches ON for the S2 DIP.
Zone
Value
1
2
4
256
512
2048
1
256
X
2
512
X
3
768
X
X
4
1024
5
1280
X
6
1536
X
7
1792
X
X
8
2048
X
9
2304
X
X
10
2560
X
X
11
2816
X
X
X
12
3072
X
13
3328
X
X
14
3584
X
X
15
3840
X
X
X