Continental AXC Fan Brochure

www.continentalfan.com
DRYER BOOSTER FANS
DVK DRYER BOOSTER FAN
The DVK Dryer Booster Fan is designed to enhance the drying efficiency of a dryer. It is capable of overcoming a long duct run, and
the in-line design simplifies installation. Unique features result in a quiet and powerful dryer boosting solution.
FEATURES & BENEFITS
Boost dryer exhaust efficiency, reduce drying times, and deliver cost savings
External rotor motor design for quiet and efficient operation
Backward-curved centrifugal impeller to ove
rcome long duct runs
In-line construction to reduce lint build-up
Heavy gauge, drawn steel housing with baked epoxy finish
High temperature construction: 60 C/140 F
Thermal overload protection
Automatic reset
ACCESSORIES / OPTIONS
Controls - pages 36-37 Accessories - pages 38-39
BOOSTER FAN ACTIVATION METHODS
Current Sensor (DVK100B-C Kit)
This is the preferred method for activating a dryer booster fan. When a
clothes dryer is operating and drawing at least one amp of current, the
current sensor automatically activates the DVK100B dryer booster fan.
Pre
ssure Switch (DVK100B-P Kit)
The pressure switch is designed to be mounted in the duct between the
fan and the dryer. When it senses dryer airflow, the switch activates the
DVK100B dryer booster fan.
Pressure Switch - Mounted (DVK100B-PM Kit)
The pre-mounted pressure switch si
mplifies installation. Utilizing the
components found in the DVK100B-P kit, the pressure switch is pre-wired
and factory mounted to the DVK100B dry
er booster fan.
Each of the above booster fan activation methods may be purchased as a separate accessory item.
Note: Continental Fan does not recommend wiring a dryer booster fan directly into a clothes dryer.
INSTALLATION TIPS
DVK100B fans should be mounted at least 15 linear feet from dryer.
Each 90-degree elbow is equivalent to 5 linear feet of duct.
DVK100B fans are designed to vent up to 110 feet of 4-inch rigid duct.
HELPFUL HINTS
A LT100 Lint Trap may be installed between the dryer and the booster fan to reduce lint build-up and maintenance on the fan.
MODEL WATTS RPM
0”
SP
0.2
SP
0.4”
SP
0.6”
SP
0.8”
SP
1.0”
SP
1.2”
SP
1.5”
SP
DVK100B 83.4 2620 150 140 127 112 94 74 53 23
MODEL D d a B
SHIP WT
(LBS)
DVK100B 9.5 3.9 1.0 8.3 8.0
DIMENSIONS IN INCHES
AIRFLOW PERFORMANCE (CFM)
*DO NOT USE FOR CONSTRUCTION CONSULT FACTORY FOR CERTIFIED PRINTS
LT100
Lint Trap
DVK Kit
RC100
Roof Cap
10