Continental AXC Fan Brochure

ENERGY RECOVERY VENTILATORS
OPERATION MODES
Natural Airflow
Shutter is open; fan does not run.
Air flows freely through ventilator and is purified by filters.
Supply Mode
Ventilator continuously draws in fresh air from outside.
Air is purified by the filters.
Ventilation Mode
Ventilator operates in permanent supply or extract mode.
Synchronized units can provide balanced ventilation.
Regeneration Mode
Ventilator alternates between supply and exhaust every 70 seconds.
Thermal energy is recovered, and the humidity setting is maintained.
Cycle I
Warm stale air is extracted from the room. It heats and moisturizes the ERV
core, transferring up to 90% of thermal energy. In 70 seconds, the ventilator
switches to supply mode.
Cycle II
Fresh outside air flows through the ventilator, absorbing the accumulated
moisture and thermal energy in the ERV core and supplying warmed air into
the room. In 70 seconds, the ventilator switches back to extraction mode.
SPECIFICATIONS
MODEL
MANUFACTURE
CODE
THERMAL
RECOVERY
SPEED RPM
SONES
@ 3M
WATTS AMPS CFM
TRANSPORTED
AIR TEMP. (F)
POWER
SUPPLY
ECO-FLO RA1-50-2 90%
Low 610 0.2 3.80 0.024 8
From -4
up to 122
120 V
60 Hz
1 Phase
Med 800 0.4 3.96 0.026 16
High 1450 0.5 5.61 0.039 32
Ø6”
Ø6.19”
8.38” 9.44”10.25”
4.75” - 18.50”5.56” 4” 5”11.81”
12.19”
PERFORMANCE
IP24 protection