Continental AXC Fan Wiring-Diagram

TITLE
BY
DATE
REV. DATE BY
Better Airflow By Design
CFM
DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE.
DRAWING NOT TO BE USED FOR CONSTRUCTION.
GREEN
WHITE
BLACK
CAPACITOR
TERMINAL
BLOCK
BLACK
WHITE
GROUND
BROWN
BLACK
BLUE
YELLOW
117 VOLT SUPPLY
FROM FUSE PANEL
WHITE JUMPER
AXC FAN MOTOR
NOTE:
JUMPER MUST BE USED WHEN FAN IS OPERATED WITHOUT VARIABLE SPEED CONTROL
WIRING DIAGRAM
BASIC FAN WITHOUT CONTROLS
J. E. EVANS 25 SEPT. 2007 A103297
01 30 NOV. 2011 JEE