INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE. NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE. 1 INSTALLATION AND OPERATING INSTRUCTIONS CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACES HEATERS. BCDV40-N NATURAL GAS CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
TABLE OF CONTENTS 1.0 2.0 3.0 INSTALLATION OVERVIEW INTRODUCTION 3 4 2.1 2.1.1 2.1.2 2.1.3 2.2 2.3 2.4 5 5 5 5 6 7 7 VENTING 3.1 3.2 3.3 3.3.1 3.4 3.5 3.6 3.7 3.8 3.9 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.
1.0 INSTALLATION OVERVIEW Top, see “COUNTER TOP / BAR INSTALLATION” section. Venting, see “VENTING” section. Bricks, see “BRICK PANEL INSTALLATION” section. . Louvre, see “LOUVRE INSTALLATION” section. Rating plate, see “RATING PLATE INFORMATION” section. Door, see ”DOOR INSTALLATION” section. Door, see ”END DOOR INSTALLATION” section. W415-0812 / D / 08.16.
2.0 INTRODUCTION ! • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • WARNING THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. ANY CHANGES TO THIS APPLIANCE OR IT’S CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fire or injury. Risk of fire or asphyxiation do not operate appliance with fixed glass removed.
2.1 DIMENSIONS 2.1.1 PENINSULA 22 1/8" 5" DIA. 8" DIA. 38" 32 1/2" GAS INLET 6 /2" 4 1/4" 1 36" 37 5/8" 38 5/8" 2 1/2" 22 1/8" ELECTRICAL INLET 2.1.2 OPEN-END 22 1/8" 5" DIA. 8" DIA. 38" 32 1/2" 6 /2" 4 1/4" 1 36" 37 5/8" 38 5/8" GAS INLET 2 1/2" ELECTRICAL INLET 22 1/8" 25 1/8" 2.1.3 SEE-THRU 22 1/8" 5" DIA. 8" DIA. 38" 32 1/2" 6 /" 4 /" 12 14 36" 40 5/8" GAS INLET 22 1/8" 2 1/2" ELECTRICAL INLET W415-0812 / D / 08.16.
2.2 GENERAL INSTRUCTIONS ! WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPENED OR REMOVED. PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE. PROVIDE ADEQUATE VENTILATION. NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48” FROM THE FRONT FACE OF THE APPLIANCE. SURFACES AROUND AND ESPECIALLY ABOVE THE APPLIANCE CAN BECOME HOT.
2.3 GENERAL INFORMATION FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! NG LP Altitude (FT) 0-4,500 0-4500 Max. Input (BTU/HR) 30,000 30,000 Max. Output Steady State (BTU/HR) 20,400 20,400 Min. Inlet Gas Supply Pressure 4.5" Water Column 11" Water Column Max. Inlet Gas Supply Pressure 7" Water Column 13" Water Column 3.
3.0 VENTING ! WARNING RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE. IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3 FEET FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLES. USE WOLF STEEL LTD.
3.1 VENTING LENGTHS AND COMPONENTS Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to. For Simpson DuraVent, Selkirk Direct Temp, American Metal Amerivent and Metal-Fab follow the installation procedure provided with the venting components.
3.2 TYPICAL VENT INSTALLATIONS 16" MIN 40 FT MAX 34" MIN 24" MAX 38" MIN PLUS RISE* When venting, the horizontal run must be kept to a maximum of 20 feet. If a 20 foot horizontal run is required, the appliance must have a minimum vertical rise immediately off the appliance of 57". 37 3/4" When terminating vertically, the vertical rise is a minimum 34" and a maximum 40 feet above the appliance. When installing with no vertical rise, ensure that the vent pipe does not slope downward.
3.3 SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12” above grade. The maximum allowable vent length is 10’ for a fireplace and 8’ for a stove. 12" MIN TO GRADE 24" MIN REGARDLESS OF HORIZONTAL VENT LENGTH 37 3/4" MIN 9.5A W415-0812 / D / 08.16.
3.4 VENT TERMINAL CLEARANCES COVERED BALCONY APPLICATIONS ††* Q R INSTALLATIONS CANADA U.S.A. S G Q MIN = 3 feet R MAX = 2 x Q ACTUAL R MAX feet P A 12” 12” Clearance above grade, veranda porch, deck or balcony. B 12” Δ 9” Δ Clearance to windows or doors that open. C 12” * 12” * Clearance to permanently closed windows.
3.5 VENT APPLICATION FLOW CHART TOP EXIT Horizontal Termination Vertical Termination Vertical rise is equal to or greater than the horizontal run Vertical rise is less than horizontal run Vertical rise is equal to or greater than the horizontal run Vertical rise is less than horizontal run Horizontal run + vertical rise to maximum of 40 feet Horizontal run + vertical rise to maximum of 24.
3.8 HORIZONTAL TERMINATION (HT) < (VT) See graph to determine the required vertical rise VT for the required horizontal run HT. Simple venting configuration (only one 45° and 90° elbow) 39 REQUIRED VERTICAL RISE IN FEET VT 40 30 20 10 0 2.5 5 7.5 10 12.5 15 17.
(HT) > (VT) Simple venting configuration (only one 45° and 90° elbow) See graph to determine the required vertical rise VT for the required horizontal run HT. 147” REQUIRED VERTICAL RISE IN INCHES VT 150 100 57” 50 0 5 15 10 20 12.5’ HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT The shaded area within the lines represents acceptable values for HT and VT For vent configurations requiring more than one 45° elbow and 90° elbow, the following formulas apply: Formula 1: HT < 4.
3.9 VERTICAL TERMINATION (HT) < (VT) Simple venting configurations. See graph to determine the required vertical rise VT for the required horizontal run HT.
(HT) > (VT) Simple venting configurations. See graph to determine the required vertical rise VT for the required horizontal run HT. 19 REQUIRED VERTICAL RISE IN FEET VT 20 10 3 0 5 10 15 25 20 30 HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT The shaded area within the lines represents acceptable values for HT and VT For vent configurations requiring more than one 45° and one 90° elbow, the following formulas apply: Formula 1: HT < 3VT Formula 2: HT + VT < 40 feet 45° Example: V1 = 1 FT V2 = 1.
4.0 PENINSULA INSTALLATION 4.1 VENTING Refer to "VENTING" section. All venting must have a minimum clearance of 2" to combustible material on the top and 1" to the sides and bottom. 4.2 FRAMING ! WARNING RISK OF FIRE! IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE APPLIANCE ENCLOSURE BE “FINISHED” (IE: DRYWALL / SHEETROCK), AS YOU WOULD FINISH ANY OTHER OUTSIDE WALL OF A HOME.
Care should be taken to maintain sufficient clearance for the vent installation. A horizontal vent installation requires a minimum height of 45" using flexible vent pipe, to the underside of the enclosure top including the 2" clearance to combustibles 2" CLEARANCE TO COMBUSTIBLES 20" MINIMUM INSIDE DIMENSION 7" 7" 45" MINIMUM 4.3 COUNTER TOP / BAR INSTALLATION When finishing the appliance, combustible material may rest directly on the top extension.
4.4 BRICK PANEL INSTALLATION Install the base panels as illustrated. The side panel sits under the bracket tab. Holding the side panel in position, bend down the tab to secure. STEP 1 STEP 2 STEP 3 STEP 4 RETAINER STEP 5 DETAIL 5 4.5 FACING Combustible materials may be installed flush with the front of the appliance but must not cover any of the black face-areas of the appliance. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.
5.0 OPEN-END INSTALLATION 5.1 VENTING Refer to "VENTING" section. All venting must have a minimum clearance of 2" to combustible material on the top and 1" to the sides and bottom. 5.2 FRAMING ! WARNING RISK OF FIRE! IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE APPLIANCE ENCLOSURE BE “FINISHED” (IE: DRYWALL / SHEETROCK), AS YOU WOULD FINISH ANY OTHER OUTSIDE WALL OF A HOME.
5.3 BRICK PANEL INSTALLATION Install the base panels as illustrated in steps 1-4, see "PENINSULA INSTALLATION PROCEDURE" section. The side panel sits under the bracket tab. Holding the side panel in position, bend down the tab to secure. DETAIL 6. STEP 5 RETAINER DETAIL 6 5.4 STEP 6 FACING Combustible materials may be installed flush with the front of the appliance but must not cover any of the black face-areas of the appliance.
6.0 SEE-THRU INSTALLATION 6.1 VENTING Refer to "VENTING" section. All venting must have a minimum clearance of 2" to combustible material on the top and 1" to the sides and bottom. 6.2 FRAMING ! WARNING RISK OF FIRE! IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE APPLIANCE ENCLOSURE BE “FINISHED” (IE: DRYWALL / SHEETROCK), AS YOU WOULD FINISH ANY OTHER OUTSIDE WALL OF A HOME.
6.3 BRICK PANEL INSTALLATION Install the base panels as illustrated in steps 1-4, see "PENINSULA INSTALLATION PROCEDURE" section. Both side panels sit under the bracket tab. Holding the side panel in position, bend down the tab to secure. DETAIL 6. RETAINER STEP 5 DETAIL 5 & 6 RETAINER STEP 6 6.4 FACING Combustible materials may be installed flush with the front of the appliance but must not cover any of the black face-areas of the appliance.
7.0 FRAMING 7.1 MINIMUM CLEARANCE TO COMBUSTIBLES Minimum clearance to combustible construction from appliance and vent surfaces: Sides, back, bottom, and top 0" Vent pipe side, bottom and top* 2" Recessed depth (corner installation) 25¼" Ceiling 54" from bottom of appliance. Enclosure 38" from bottom of appliance. * HORIZONTAL VENT SECTIONS: A minimum clearance of 1" at the bottom and sides and 2" at the top of the vent pipe on all horizontal runs to combustibles is required.
7.3 ALCOVE INSTALLATION RECESS OR ALCOVE AREA ENCLOSURE AREA APPLIANCE NOTE: Recesses or alcoves above the appliance can be made as deep as desired provided the minimum clearances to combustibles are maintained. Non-combustible material can be used, provided the minimum clearances to combustible materials are applied. The minimum enclosure volume must be increased by no less than the volume of the recess.
7.4 MINIMUM MANTEL CLEARANCES ! WARNING RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE CLEARLY MAINTAINED. WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE HEAT RESISTANT TO PREVENT DISCOLOURATION. 73.1 Combustible mantel clearance can vary according to the mantel depth.
8.0 INSTALLATION ! WARNING FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS EXACTLY. ALL INNER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING EITHER RED RTV HIGH TEMP SILICONE SEALANT W573-0002 (NOT SUPPLIED) OR BLACK HIGH TEMP MILL PAC W573-0007 (NOT SUPPLIED) WITH THE EXCEPTION OF THE APPLIANCE EXHAUST FLUE COLLAR WHICH MUST BE SEALED USING MILL PAC.
8.1.1 HORIZONTAL INSTALLATION ! WARNING THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP. TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN FLANGE OF THE MOUNTING PLATE. This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal location, cut and frame a hole in the exterior wall as illustrated to accommodate the firestop assembly.
8.1.2 VERTICAL INSTALLATION This application occurs when venting through a roof. Installation kits for various roof pitches are available from your authorized dealer / distributor. See accessories to order specific kits required. A. Determine the air terminal location, cut and frame a square opening as illustrated in the ceiling and the roof to provide the minimum 1“ clearance between the vent pipe and any combustible material.
8.2.1 HORIZONTAL AIR TERMINAL INSTALLATION A. B. Stretch the inner flex pipe to the required length taking into account the additional length needed for the finished wall surface. Apply a heavy bead of the high temperature sealant W573-0007 Mill Pac (not supplied) to the inner sleeve of the air terminal. Slip the vent pipe a minimum of 2” over the inner sleeve of the air terminal and secure with 3 #8 screws.
8.2.2 VERTICAL AIR TERMINAL INSTALLATION ! WARNING MAINTAIN A MINIMUM 2” SPACE BETWEEN THE AIR INLET BASE AND THE STORM COLLAR. A. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. B. Stretch the inner flex pipe to the required length.
8.2.3 APPLIANCE VENT CONNECTION A. Install the inner flex pipe to the appliance. Secure with 3 screws and flat washers. Seal the joint and screw holes using the high temperature sealant W573-0007 (not supplied). B. Install the outer flex pipe to the appliance. Attach and seal the joints using the high temperature sealant W573-0002 (not supplied). #8 X 1/2” SELF DRILLING SCREWS 2” OVERLAP HIGH TEMPERATURE SEALANT 28.2 8.3 GAS INSTALLATION ! WARNING RISK OF FIRE, EXPLOSION OR ASPHYXIATION.
8.4 OPTIONAL WALL SWITCH INSTALLATION ! WARNING DO NOT CONNECT EITHER THE WALL SWITCH, THERMOSTAT OR GAS VALVE DIRECTLY TO 110 VOLT ELECTRICITY. For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route a 2 strand, solid core millivolt wire from the valve to the wall switch or millivolt thermostat. The recommended maximum lead length depends on wire size: WIRE SIZE MAX.
9.0 FINISHING ! WARNING RISK OF FIRE! NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED. DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS REMOVED, CRACKED, BROKEN OR SCRATCHED. FACING AND/OR FINISHING MATERIAL MUST NEVER OVERHANG INTO THE APPLIANCE OPENING. 72.1A 9.
9.3 HEAT SHIELD STAND-OFF REMOVAL (SEE-THRU INSTALLATION ONLY) When using a non-combustible finishing material, the stand-offs may be removed, by removing the set screw in the centre and sliding the stand-offs out of the mounting clips. * The top extension may be removed if non-combustible framing is faced with a non-combustible material placed flush with the front face of the appliance and extending from the top of the appliance. Example: Cement board (not supplied).
9.5 LOG PLACEMENT ! WARNING FAILURE TO POSITION THE LOGS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY LOGS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE. DO NOT MODIFY THE PROPER LOG POSITIONS, SINCE APPLIANCE MAY NOT FUNCTION PROPERLY AND DELAYED IGNITION MAY OCCUR. THE LOGS ARE FRAGILE AND SHOULD BE HANDLED WITH CARE. 76.
E. When pieces #3a and #3b are attached to create log #3, the upper end of log #3 should rest in the groove, on top of log # 2. The slot in the underside of piece #3b fits over #3a. Place the end of piece #3b onto the pin. F. As with log # 1, log #4 is also cradled by the texture of the burner and the pin in the base. Position log #4 so that the lower end fits onto the pin. The upper end rests against the moulded locator on the top of log # 1. G. Like log #3, log #5 also comes in two pieces.
10.0 OPTIONAL BLOWER INSTALLATION ! WARNING RISK OF FIRE AND ELECTRICAL SHOCK. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE. USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
11.0 OPERATION ! WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED. Ensure that a continuous gas flow is at the burner before installing the door. When lit for the first time, the appliance will emit an odor for a few hours.
12.0 ADJUSTMENTS 12.1 PILOT BURNER ADJUSTMENT Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow. PILOT BURNER THERMOPILE Inlet pressure can be checked by turning screw (A) THERMOCOUPLE counter-clockwise until loosened and then placing pressure gauge tubing over the test point. Gauge should read 7” (minimum 4.5”) water column for natural gas or 13” (11” minimum) water column for propane. Check that main burner is operating on “HI”.
12.3 FLAME CHARACTERISTICS It’s important to periodically perform a visual check of the pilot and burner flames. Compare them to the illustration provided. If any flames appear abnormal call a service person. PILOT BURNER ELECTRODE FLAME SENSOR FLAME MUST ENVELOP UPPER 3/8” TO 1/2” OF FLAME SENSOR 54.1A 12.4 RESTRICTING VERTICAL VENTS Vertical installations may display a very active flame. If this appearance is not desirable, the vent exit must be restricted using a restrictor vent kit.
13.0 MAINTENANCE MAINTENANCE ! WARNING MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
14.0 REPLACEMENTS ! WARNING FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. ** THIS IS A FAST ACTING THERMOCOUPLE. IT IS AN INTEGRAL SAFETY COMPONENT. REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD. Contact your dealer or the factory for questions concerning prices and policies on replacement parts.
SEE-THRU COMPONENTS REF NO. PART NO. DESCRIPTION 3* W562-0009 DOOR GASKET (100") 16* W475-0516 END FIBRE BRICK PANEL - FOR WALL 29 N010-0323 END DOOR HEAT SHIELD 30 W200-0117 END DOOR COVER PENINSULA COMPONENTS REF NO. PART NO. DESCRIPTION 28 W500-0192 END BRICK PANEL RETAINER 31 W010-0516 BLACK SIDE DOOR C/W GLASS 26 W010-0873 END DOOR TEMPERED GLASS C/W GASKET REF NO. PART NO.
20 28 25 26 30 29 23 31 14 24 3 41 27 33 37 39 40 38** 42 35 34 32 6 15 4 18 17 16 8 7 13 22a 9 12 22b 10 11 W415-0812 / D / 08.16.
ACCESSORIES REF NO. PART NO.
15.0 TROUBLESHOOTING ! WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. SYMPTOM Main burner goes out; pilot stays on. Main burner goes out; pilot goes out. Pilot goes out when the gas knob is released.
SYMPTOM PROBLEM Pilot will not light. No spark at pilot burner. TEST SOLUTION - Check if pilot can be lit by a match. Check that the wire is connected to the push button igniter. Check if the push button igniter needs tightening. Replace the wire if the wire insulation is broken or frayed. Replace the electrode if the ceramic insulator is cracked or broken. Replace the push button ignitor Out of propane gas. - Fill the tank. Spark gap is incorrect. - Spark gap should be 0.150” to 0.
16.0 WARRANTY CONTINENTAL® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2008 Quality Assurance Certificate. CONTINENTAL® products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station.
17.0 SERVICE HISTORY 43.1 W415-0812 / D / 08.16.
W415-0812 / D / 08.16.