Installation manual

25
IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact
Continental Girbau, Inc.
®
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the left side panel area behind the top control (access) door. In the case of
208 VAC or 230/240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC AND 230/240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: The manufacturer reserves the right to make changes in specifications at any time without
notice or obligation.
CG75-85 (GAS/STEAM)
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT:
NOTES: A.
B.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When
ordering, specify exact voltage.
Circuit breakers are thermal/magnetic (industrial) motor curve type
ONLY. For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker to be used.
Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
CIRCUIT
BREAKER
AMPERAGE
60 Hz 50 Hz
120 2 12 - 25
208 2 7.1 - 15
240 2 6.5 - 15
208 3/4 4.7 - 15
240 3 4.9 5.5 15
380-400 3/4 - 2.9 15
416 3/4 - 3.1 15
460/480 3/4 2.8 - 15