User Manual

Values, dimensions and reference in this brochure are approximate and intended as guide only, not for construction and are subject to change without notice
DETAILED ENGINEERING DESCRIPTION - CONTINENTAL INDUSTRIE
DEB077EN – 04/2010
4/4
12.0 Recommended maximum allowable Piping forces and moments on blower
connections
12.1 Inlet flange
FX
= 40 KG
FY
= 100 Kg
FZ
= 80 Kg
MX
= 60 kgm
MY
= 30 kgm
MZ
= 30 kgm
12.2 Outlet flange
FX
= 40 KG
FY
= 100 Kg
FZ
= 80 Kg
MX
= 60 kgm
MY
= 30 kgm
MZ
= 30 kgm
where :
F
= force
M
= moment
X
= Axial - parallel to rotor centre line
Y
= Vertical
Z
= Horizontal - normal to rotor centre line.
13.0 Vibration and noise
Vibration tolerance: 4,5 mm/s RMS
Vibration shall not exceed 4,5 mm/s RMS when measured in the vertical plane at the
bearing housings with the blower operating at the design speed.
Sound level: please refer to the calculation data sheet
II - PERFORMANCES
1.
All tests if required are in conformity with ASME Power Test Code.
2.
For constant speed blowers:
-
The head shall be within the range of 100% - 105% of the normal head at design capacity,
-
The horsepower based on measured head shall not exceed 107% of the value at the specified
normal operating point.
3.
For variable speed machines:
-
through the rotational speed, the head shall be adjusted as close as possible to the design point,
with zero negative tolerance,
-
the horsepower at that point shall not exceed 104% of the predicted shaft power value.