Owners Manual
17
OPERATIONS MANUAL
 REACH-INS & ROLL-INS
a. The display will illuminate with the current cabinet    
   temperature.
b. The compressor icon, fan icon, and the aux heater icon
   may flash for a period of time, indicating normal
   delayed start-up.
c. After the start-up delay, the compressor and evaporator
   fan(s) will start if the control is calling for cooling.
a. The SET-POINT is the preprogrammed temperature which
   shuts off the compressor.
b. The DIFFERENTIAL is the preprogrammed temperature that
   is added to the SET POINT temperature that will start the
   compressor.
a. During defrost, the defrost icon will appear in the display 
   and the compressor will turn off until a preprogrammed
   temperature or time is reached. During this time for freez-
   ers only, the evaporator fan(s) will also turn off and the
   defrost heater will be energized.
b. After a preprogrammed evaporator temperature has been
   reached, there may be a short delay for both the compres-
   sor and evaporator fan(s) to restart.
c. After the defrost cycle is completed, the control will  
   resume normal operation.
EXAMPLE: Set-Point  36°F and  the differential  is  4°F the  com-
pressor will cycle off at 36°F and back on at 40°F.
COMPRESSOR
EVAP FAN
DEFROST
AUX HTRS
ALARM
ELECTRONIC CONTROL DISPLAY AND BUTTONS
The  control  icons  shown  above  will  be  illuminated  when  the 
associated function is active. If an icon is flashing, it means the 
function will be activated after the controller delays are finished.
•  The “AUX HTRS/UP” button is used for activation or 
deactivation of the auxiliary anti-condensate heaters or for 
increasing values.
•  The “SET/MUTE” button is used to lock in a new value or 
to silence the alarm beeper.
•  The “POWER/DOWN” button is used to turn the unit on/off 
or for decreasing values. 
•  Press the “UP” and “DOWN” buttons simultaneously for 3 
seconds to put into manual defrost.
NOTE: The electronic control has 2 or 3 probes. There is 
the regulation probe in the return air stream, there is an 
evaporator probe located in the evaporator coil, and if the 
unit has fascia heaters, there will be an ambient probe.
INITIAL SEQUENCE OF OPERATION
1.  Cabinet is plugged in.
2.  The control will cycle the compressor on and off determined 
by the SET-POINT and DIFFERENTIAL.
3.  The control may be preprogrammed to initiate a defrost by 
time interval.
HOW TO CALIBRATE THE ELECTRONIC CONTROL
The controller temperature display can be calibrated if required.  
Before attempting to calibrate the temperature display, check the 
display by placing a pre-calibrated temperature sensing device in 
the center of the refrigerated compartment and keep the doors 
closed for at least 15 minutes. The temperature display should 
read the same temperature as the sensing device, within +/-2°F.  
If not, follow these instructions to calibrate.
1.  Press and HOLD the “SET” button until “PS” appears flash-
ing in the display. Release the “SET” button.
2.  Press  the  “UP”  button  until  “/C1”  appears  in  the  display.  
Release the “UP” button.
3.  Press and release the “SET” button. The current value of the 
offset will appear in the display.
4.  Press the “UP” button to increase or the “DOWN” button to 
decrease the offset value.
5.  Press and HOLD the “SET” button for 5 seconds to confirm 
and save the new value. When complete, the current tem-
perature will be displayed. RELEASE the “SET” button.
EXAMPLE: If a sensing device in the cabinet reads 38°F and the 
control display shows 41°F, follow steps above and decrease the 
current offset by 3°F. If the current offset was 0, change to -3.
HOW TO CHANGE THE SET-POINT
Refrigerators are factory set to maintain an average temperature 
of 38°F. Freezers are factory set to maintain an average tempera-
ture of 0°F. To change set-point:
1.  Press and HOLD the “SET” button until the current set-point 
begins flashing. Release the “SET” button.
2.  Press the “UP” or “DOWN” button to adjust to the new set-
point value.
3.  Press and release the “SET” button to lock in the new set-
point. The control will now resume normal operation with 
the new set-point.
AUX HTRS
(UP)
SET 
(MUTE)
POWER 
(DOWN)
DEFROST
2 BUTTONS