Owners Manual
20
 REACH-INS & ROLL-INS      
OPERATIONS MANUAL     
IMPORTANT NOTE: LOADING PRODUCT TOO CLOSE 
TO THE WALLS OR PANELS WILL RESTRICT AIRFLOW, 
RESULTING IN POOR PERFORMANCE AND SERVICE 
ISSUES, SUCH AS COIL FREEZE-UP, WHICH WILL NOT 
BE COVERED BY WARRANTY.
To ensure proper air flow inside wall your cabinet, some interior 
standard models are provided with product stops that snap onto 
the shelves (see Figure 10B). To install the product stop, place 
it over the shelf as shown and press it down onto the shelf. If 
necessary,  carefully  pull  out on  the  ends of  the product  stop, 
so the bottom of the rod snaps over the shelf wire. Press down 
on the hooks at ends of the product stop, so they snap over the 
back of the shelf frame. Repeat for remaining shelves. Make sure 
all shelves are installed with the product stops positioned at the 
back of your cabinet.
INTERIOR ACCESSORIES
Your new cabinet comes with (3) shelves per section for stan-
dard solid door models, or (4) shelves per section for glass door 
models, and (4) support clips per shelf.
SHELVING INSTALLATION
Pilaster strips for mounting the shelves are secured to the cabi-
net walls with special screws which allow the strips to be readily 
removed  for  cleaning  without  the  use  of  tools.  To  install  the 
shelving, determine the desired location for the shelves in each 
section of your cabinet. For proper airflow, the bottom shelf in 
each section should be installed with the clips at the lowest posi-
tion on the pilaster strip, to provide space for sufficient airflow 
under and around the product.
IMPORTANT NOTE:  When  locating  your  shelves,  allow 
space between  each row of  product. A minimum  clear-
ance  of  2”  is  recommended  below  the  bottom  product 
for air circulation.
Shelf clips are easily installed by inserting them into the pilasters 
at the desired shelf locations. To install a shelf, simply place it 
on the (4) clips, making sure that the clips are located properly, 
so the shelf is level and supported at each corner. Standard and 
optional heavy duty pilasters and clips are shown in Figure 10.
PRODUCT LOADING
Product  load  should  be  evenly  distributed  over  each  shelf 
and through  the cabinet.  For proper  performance on  standard 
ceiling-mount coil models, maintain at least a 2” air space from 
product to the back wall and to the coil housing. For top-mount 
plug box models, a minimum 2” clearance should be maintained 
from the face of the top and side walls (see Figure 10A).
FIGURE 10: Standard and Heavy Duty Shelf Supports
FIGURE 10A: Product Loading Limits
FIGURE 10B: Product Stop Installation