INSTALLATION AND OPERATIONS MANUAL Refrigerated Griddle Stands Refrigerators & Freezers Please fill in the following information for your NEW unit, carefully read the instructions in this manual and file it for future reference. MODEL NO. SCAN this code to download manual SERIAL NO. PURCHASED FROM INSTALL DATE 1-800-523-7138 Continental Refrigerator A Division of National Refrigeration & Air Conditioning Products, Inc. 539 Dunksferry Road Bensalem, PA 19020-5908 P 215-244-1400 F 215-244-9579 www.
TABLE OF CONTENTS Page Receiving Your New Model.............................................................................................................. 3 General Information and Important Operating Facts................................................................................. 3 Serial Data Tag........................................................................................................................................................3 Uncrating Your New Model........
REFRIGERATED GRIDDLE STANDS RECEIVING YOUR NEW MODEL Congratulations on your purchase of Continental Refrigerator superior foodservice equipment! When your shipment arrives, thoroughly examine the packaging for any punctures, dents or signs of rough handling. It is in your best interest to partially remove or open the shipping container to examine the contents for any missing accessories or concealed damage which may have occurred during shipment.
REFRIGERATED GRIDDLE STANDS Four (4) bolts secure the cabinet to the wooden skid. The bolts are located at each end on the underside of the skid. In order to remove these bolts, tilt the cabinet backwards and place wooden blocks at each end in order to hold it in its tilted position. Using a ¾” socket or open end wrench, remove the bolts and carefully slide the cabinet off of the skid.
REFRIGERATED GRIDDLE STANDS FLOOR LOADS The floor at the final location site must be level, free of vibration and strong enough to support the total combined weights of your new model plus the maximum product load which might be placed into it. Keep in mind that all the weight is concentrated at the caster or leg locations. To estimate the possible product weight, assume that each cubic foot of storage space weighs approximately 35 pounds.
REFRIGERATED GRIDDLE STANDS CONDENSATE REMOVAL No floor drains or plumbing connections are required since all models use an automatic condensate water evaporating system (see Figure 4) which is completely self-contained and no further assembly or maintenance is required. In some adverse conditions such as high ambient temperature, high humidity, extremely heavy usage, frequent loading for prolonged periods of time, or heavy pan loading, the amount of condensate water generated could overflow the pan.
REFRIGERATED GRIDDLE STANDS REMOVAL OF DRAWERS AND DRAWER ADJUSTMENTS To remove the drawers from the cabinet, slide each drawer out until it stops. Unhook the stop clip at the front of the left and right-hand drawer slide (see Figure 5) by pushing the clip forward and pressing down on the top back edge as shown. Lift the drawer slightly as you pull it the rest of the way out. Larger drawers may require two people. The center member, with the wheels attached, will remain in the cabinet.
REFRIGERATED GRIDDLE STANDS INITIAL CLEANING PROCEDURE Prior to start-up and before placing any product inside of your new model, the interior of the cabinet should be thoroughly cleaned. Remove the protective film (which is clear on some models) from all interior sides, bottom and other internal metal panels, by working the corner loose and slowly pulling the film back.
REFRIGERATED GRIDDLE STANDS SPECIAL VOLTAGE CONNECTIONS When models are ordered from the factory with special, optional voltages, connections should be made as required on the electrical wiring diagram provided on the inside compressor compartment rear next to the electrical console box.
REFRIGERATED GRIDDLE STANDS REFRIGERATION SYSTEM AND ADJUSTMENT All self-contained refrigerators are designed and factory set to maintain an average cabinet temperature of 38° to 40°F (3.3° to 4.4°C). On Griddle Stand models, the temperature control is located behind the front grill, on the side wall of the machine compartment (see Figure 4).
REFRIGERATED GRIDDLE STANDS ELECTRONIC CONTROL DISPLAY AND BUTTONS 3. COMPRESSOR EVAP FAN DEFROST AUX HTRS ALARM The control icons shown above will be illuminated when the associated function is active. If an icon is flashing, it means the function will be activated after the controller delays are finished. AUX HTRS (UP) DEFROST 2 BUTTONS SET (MUTE) POWER (DOWN) • • • • The “AUX HTRS/UP” button is used for activation or deactivation of the auxiliary anti-condensate heaters or for increasing values.
REFRIGERATED GRIDDLE STANDS HOW TO SWITCH THE CONTROLLER OFF/ON The controller can be switched OFF. The display will still be active but all systems operated by the control will be OFF. 1. To turn the controller OFF, press and HOLD “POWER” button for 5 seconds. When in the OFF mode, “OFF” will alternate in the display with the current appliance temperature. 2. To turn the controller back “ON”, press and HOLD “POWER” button for 5 seconds. The controller will resume normal operation.
REFRIGERATED GRIDDLE STANDS MAINTENANCE SAFETY PRECAUTIONS DISCONNECT POWER BEFORE ATTEMPTING TO WORK ON OR CLEAN EQUIPMENT. DO NOT ATTEMPT TO REMOVE ANY COVERS OR PARTS YOURSELF, AS THIS CAN EXPOSE DANGEROUS, HIGH VOLTAGE WIRING. SERVICE SHOULD ONLY BE PERFORMED BY A QUALIFIED TECHNICIAN. ALWAYS ROUTE POWER CORDS AWAY FROM AREAS WHERE THEY CAN BE WALKED ON OR DAMAGED BY OTHER EQUIPMENT. YOUR APPLIANCE IS EQUIPPED WITH A POLARIZED, GROUNDED POWER PLUG.
REFRIGERATED GRIDDLE STANDS CARE AND CLEANING OF STAINLESS STEEL* DO NOT USE: abrasive cleaners, chemicals with chlorides or muriatic acid to clean your equipment. *Some information and graphics for this section were obtained from “Stainless Steel Equipment Care and Cleaning” brochure, published by the North American Association of Food Equipment Manufacturers (NAFEM).
REFRIGERATED GRIDDLE STANDS PARTS AND SERVICE Continental is committed to providing the best customer service in the industry. All new units come with a Limited Extended Protection Warranty (see “Warranty” section of this manual for details). If a problem arises with your equipment, please contact our Service Department at 1-800-523-7138. One of our Service Specialists will do everything possible to solve the problem as quickly as possible.
REFRIGERATED GRIDDLE STANDS 2. All refrigerant should be removed from the system by a qualified technician and disposed of properly, or reclaimed. (Intentional venting of many refrigerants into the air is harmful and prohibited; violators are subject to fines). All refrigerant oil should be drained from the compressor and discarded appropriately. 3. Properly dispose of the cabinet and refrigeration system components.
REFRIGERATED GRIDDLE STANDS Press here to increase temp. Press here for calibration mode Press here to decrease temp. For example, if the sensing device in the cabinet reads 38° and the thermometer display reads 40°, press on the lower left corner twice so that “-2” appears on the display. After adjusting the offset, press on the right center of the display again to exit calibration mode. Wait 10 to 15 seconds for the cabinet temperature to be displayed and recheck the calibration.
REFRIGERATED GRIDDLE STANDS REMOVAL AND REPLACEMENT OF DOORS If you need to remove a door from your cabinet, first identify the location of the spring-loaded hinge cartridge (see Figure 8). Depending on the age of your cabinet, the cartridge is located either on the top or the bottom of the door.
REFRIGERATED GRIDDLE STANDS FIGURE 9: Leg Installation LEG INSTALLATION 3. 4. THREADED END 5. LEG TURN FOOT CLOCKWISE TO REDUCE HEIGHT, OR COUNTERCLOCKWISE TO INCREASE HEIGHT. BLOCKS REMOTE SET-UP AND INSTALLATION GUIDELINES All remote refrigerators and freezers are shipped with an expansion valve, thermostat, solenoid valve and defrost timer installed from the factory.
REFRIGERATED GRIDDLE STANDS TROUBLESHOOTING GUIDE PROBLEM PROBABLE CAUSE Condensing unit will not start - no hum. 1. 2. 3. 4. 5. 6. Condensing unit will not start - hums but trips on overload protector. 1. 2. 3. 4. 5. Condensing unit starts and runs, but short cycles on overload protector. CORRECTION 1. 2. 3. 4. 5. 6. Close start or disconnect switch. Replace Fuse. Determine reason and correct/replace. Relocate control. Repair or replace control. Check wiring against diagram. Improperly wired.
REFRIGERATED GRIDDLE STANDS TROUBLESHOOTING GUIDE PROBLEM Start capacitor open, shorted or blown. PROBABLE CAUSE CORRECTION 1. Relay contact not opening properly. 2. Prolonged operation on start cycle: (a) Low voltage to unit. (b) Improper relay. (c) Starting load too high. 3. Excessive short cycling. 4. Improper capacitor. 1. Clean contacts or replace relay. 2. (a) Determine reason and correct. (b) Replace with correct relay. (c) Correct by using pump down. 3.
REFRIGERATED GRIDDLE STANDS GRIDDLE STAND REFRIGERATOR 115/60/1 W/ OFF-CYCLE TIMER WD-R5-TMR WIRING DIAGRAM 22 OPERATIONS MANUAL
REFRIGERATED GRIDDLE STANDS GRIDDLE STAND REFRIGERATOR 115/60/1 W/ ELECTRONIC CONTROL WD-R5-EC WIRING DIAGRAM OPERATIONS MANUAL 23
REFRIGERATED GRIDDLE STANDS GRIDDLE STAND FREEZER 115/60/1 WD-F5 WIRING DIAGRAM 24 OPERATIONS MANUAL
REFRIGERATED GRIDDLE STANDS GRIDDLE STAND FREEZER 115/60/1 W/ SPLIT ELECTRONIC CONTROL WD-F5-EC-SP WIRING DIAGRAM OPERATIONS MANUAL 25
REFRIGERATED GRIDDLE STANDS WARRANTY United States of America & Canada THREE (3) YEAR PARTS AND LABOR WARRANTY Continental Refrigerator warrants to the original purchaser of every new Continental Refrigerator self contained unit, including all parts thereof, that such equipment is free from defects in material and workmanship, under normal use, proper maintenance and service as indicated by Continental Refrigerator installation and operation manual, for a period of three (3) years from the date of inst
A Division of National Refrigeration & Air Conditioning Products, Inc. 539 Dunksferry Road • Bensalem, PA 19020-5908 P 215-244-1400 • 1-800-523-7138 • F 215-244-9579 www.continentalrefrigerator.