MASTER/MASTER SETPOINT P1/1
The Master SP (CP-210) is the desired master speed (e.g., feet/minute) at which you want you system to
operate. The ScaledRef (MP-30) is equal to the Master SP (CP-210) when the CX-1200 is in “Run”. The
operating speed is determined directly by the Parameter Value that is in the Master SP (CP-210). The
Master SP (CP-210) is represented in EU/Tm.
The equation that governs this mode of operating is:
Scaled Ref {MP-30} = Master SP {CP-210}
Use the Max SP Mstr (CP-211) and Min SP Mstr (CP-212) to determine the maximum and minimum value
that can be entered into Master SP (CP-210). The Max SP Mstr (CP-211) and the Min SP Mstr (CP-212)
define the range for positive and negative values ( i.e. they are magnitude limits).
Run Mode
Run Mode (CP-202) sets the mode of operation and the subsequent Setpoint, that are used when your system is in
“Run”. The Setpoint and mode of operation combined, determine the Reference Speed and, if applicable, the
Reference Position. The modes of operation are:
4 = Inv Foll Mode
3 = Follower Mode
2 = Master Mode (default)
1 = Direct Mode
Master SP
Master Setpoint (CP-210) is the speed at which you want your system to operate (while in Run) when the Run Mode
(CP-202) is set to "2” (Master Mode).
Min SP Mstr
Minimum Setpoint Master (CP-212) is a lower limit to the Master SP (CP-210). It will prevent lower entries in Master SP
(CP-210).
Max SP Mstr
Maximum Setpoint Master (CP-211) is an upper limit to the Master SP (CP-210). It will prevent higher entries in Master
SP (CP-210).