Owner manual

5 - 78
P1/4
EDIT BLOCK 0
<Active Block>
0
*
0
*
0
*
0
*
Blk0 Val 1
->Line Spd SP
Blk0 Val 2
->NOT USED
Blk0 Val 3
->NOT USED
Blk0 Val 4
->NOT USED
Save Changes?
Press...
ENTER to Save
CLEAR to Discard
Press the Enter key to
save your changes or
press the Clear key to
discard your changes.
Edit Block / Save
Press the Menu key from any of the Edit Block screens to exit. If you have made changes in any of
the screens (pages 1-4), a dialog box will popup and give you the opportunity to either save or to
discard your changes.
NOTE: Once you have exited the Edit Block screen, if you change the value of a Control Parameter
in any other screen (that is not a block screen) and that change can create problems with that
Control Parameter when the block is put into use, then the error message “Invalid Blk” will flash
briefly in the error message bar. Generally this scenario would only happen if a math error or an
undefined operation were created in the block which houses the Control Parameter that changed.
For example, If you change the value of a scaling parameter which is also used in a block and the
affect that the change has on the block would create an overflow (e.g., a setpoint is too large in
relationship to CP-208) then the block would become unusable or an “invalid block.”