Appendix C: Parameter Summary Numeric Quick Reference (continued)
Feedback Sync Band (CP-336) sets a “dead-band” around the sync-mark position to allow for irregular sync marks. If
the actual sync pulse occurs inside this “dead-band”, the CX-1200 will presume an “in-sync” status, and therefore make
no sync-correction. A sync correction will be made if the sync pulse occurs outside this band. The band is defined as
± the value entered.
Minimum Value: 0 Maximum Value: 9999999
Default Value: 0.0 Units: EU
CP-337InPosnBand
In Position Band (CP-337) sets a limit on the magnitude of the PosnErr (MP-33) allowed before the CX-1200 will use the
Sync Logic (CP-204) setting to resolve the position error. If the magnitude of the Position Error is greater than the In
Position Band value the CX-1200 will follow the Sync Logic setting to resolve the position error.
Minimum Value: 0.01 Maximum Value: 9999999
Default Value: 1 Units: EU
CP-340LdSnsrDist
Lead Sensor Distance (CP-340) may be used to inform the CX-1200 of the distance from the critical contact point to the
Lead Sync sensor. Applied to the lead position only during sync pulse acceptance into the control algorithm.
Minimum Value: -999999 Maximum Value: 9999999
Default Value: 0 Units: EU
CP-341LdSnsrOfst
Lead Sensor Offset (CP-341) may be used to set a distance offset to the lead position. This offset becomes effective
immediately upon entry. Values entered will rollover at a job size, or be resolved to be within a job size.
Minimum Value: -999999 Maximum Value: 9999999
Default Value: 0.00 Units: EU
CP-347TrendJSChg%
Trend Job Size Change % (CP-347) sets a limit for the maximum allowable change to the Lead and Follower Job Size
Average values (MP-14, MP-24) that will be accepted by the CX-1200 control algorithm. This limit is applied to each job
size average independently before they are used by the CX-1200 control loop.
Minimum Value: 0 Maximum Value: 100
Default Value: 10 Units: Percent
CP-348NonSyncErrRecEn
NonSync Error Recovery Enable(CP-348) may be used to enable or disable position error recovery upon transition into
RUN state when Sync Mode (CP-203) is set for non-Sync. If disabled the CX-1200 will perform a position reset,