Appendix C: Parameter Summary Numeric Quick Reference (continued)
CP-390Cmpr3 Val
Enter a value in Cmpr3 Val (CP-390) that will be compared to the Monitor Parameter in Cmpr3 Parm (CP-382), using the
comparison type that you entered in Cmpr3 Type (CP-386). If the comparison that is established by these three
parameters is “true”, then the PLC sets the Cmpr3 Out bit (62) in the PLC to “1”.
Minimum Value: -9999999 Maximum Value: 9999999
Default Value: 200 Units: same as the selected MP
CP-391Cmpr4 Val
Enter a value in Cmpr4 Val (CP-391) that will be compared to the Monitor Parameter in Cmpr4 Parm (CP-383), using the
boundary type that you entered in Cmpr4 Type (CP-387). If the comparison that is established by these three
parameters is “true”, then the PLC sets the Cmpr4 Out bit (63) in the PLC to “1” .
Minimum Value: -9999999 Maximum Value: 9999999
Default Value: 72 Units: same as the selected Monitor Parameter
CP-396 Copy Source 1
Copy Source 1 (CP-396) identifies the CP or MP whose value is copied to Copy Dest 1 (CP-397) when a 0 to 1 transition
occurs in the Data Copy 1 PLC bit (160).
Minimum Value: 1 Maximum Value: 667
Default Value: 230 Units: CP or MP
CP-397 Copy Dest 1
Copy Dest 1 (CP-397) identifies the CP that takes on the value of the CP or MP identified by Copy Source 1 (CP-396)
when a 0 to 1 transition occurs in the Data Copy 1 PLC bit (160).
Minimum Value: 201 Maximum Value: 667
Default Value: 230 Units: CP or MP
CP-398 Copy Source 2
Copy Source 2 (CP-398) identifies the CP or MP whose value is copied to Copy Dest 2 (CP-399) when a 0 to 1 transition
occurs in the Data Copy 2 PLC bit (161).
Minimum Value: 1 Maximum Value: 667
Default Value: 235 Units: CP or MP
CP-399 Copy Dest 2
Copy Dest 2 (CP-399) identifies the CP that takes on the value of the CP or MP identified by Copy Source 2 (CP- 398)
when a 0 to 1 transition occurs in the Data Copy 2 PLC bit (161).
Minimum Value: 201 Maximum Value: 667
Default Value: 235 Units: CP or MP