Product Info

CONTRINEX AG Industrial Electronics
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 -
Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
3
*Polling time for 16 transponders without collision
TYPICAL TIMES
Time name Description
Value
Starting times
Time between the powering of the RWM and the end of the first scanning of the
transponders present
300 ms
Polling time
Time for actualization of the list of the transponders present. This time depends on the
number of collisions.
70* ms
Execution time of the commands
The execution time is defined as the time between the end of the sending of the
command and the beginning of the answer
Command
dependent
TYPICAL EXECUTION TIMES BY COMMAND TYPE
Command type Description
Value
Commands related to RWM Typical execution time 1.5 ms
Commands related to Transponder
depending on number of blocks
Typical read duration: T
R
= T
0
+ N ·T
R0
Typical write duration: T
W
= T
0
+ N ·T
W0
Duration for decoding the command - T
0
12.0 ms
Read duration for one block (32 bits) - T
R0
8.0 ms
Write duration for one block (32 bits) - T
W0
12.0 ms
Number of blocks concerned - N
Commands related to Transponder
not related to a number of blocks
Typical execution time
(e.g. Get System Info, Write AFI, Lock AFI, Write DSFID, Lock DSFID, and so on)
30 ms
Zeit / Temps / Time
Zeit / Temps / Time
SLK-Strohmversorgung
Alimentation MLE
RWM power supply
Status
Durchsuchen nach laufenden Transponder
Balayage des transpondeurs présents
Scanning of the transponders present
T
Start
T
Poll
Befehl
Commande
Command
Antwort
Réponse
Answer
Signal
Zeit / Temps / Time
Ausführungszeit
Temps d'exécution
Execution time