CONFIGURATION PARAMETER (IO-LINK / SIO MODE)
Index Sub Hex Name Access Data Type Value Default
SYSTEM
02
h
- Standard Command W uint8
5 = ParamDownloadStore, 128 = Device Reset,
130 = Restore Factory Settings, 160 = Locate device
(force all leds to blink during 30 seconds)
N/A
0C
h
- Device Access Lock R/W uint16
Parameter Access, Data Storage, Local Para-
metrization and Local User Interface Locks
0000
h
0D
h
- Profile Characteristic R uint16 No profile for identification devices - 0000
h
-
0E
h
- PD Input Descriptor R array <DataType><TypeLength><BitOffset> - [1]
h
[2]
h
[0]
h
-
0F
h
- PD Output Descriptor R array <DataType><TypeLength><BitOffset> - [1]
h
[2]
h
[0]
h
-
IDENTIFICATION
10
h
- Vendor Name R char [] “Contrinex“ -
11
h
- Vendor Text R char [] “www.contrinex.com“ -
12
h
- Product Name R char [] “RLH-C44PA-NIS“ -
13
h
- Product ID R char [] “00000000“ -
14
h
- Product Text R char [] “IO-Link RFID reader“ -
15
h
- Serial Number R char [] “00000000“ -
17
h
- Firmware Revision R char [] “2.0.0“ -
18
h
- Application Specific Tag R/W char [] <user string, 32 byte (variable length)>
<vendor spe-
cific>
READER PARAMETER PROCESS DATA
40
h
01
h
Operating Mode R/W uint8
00
h
: Scan UID
01
h
: Read / Write Command
00
h
READER PARAMETER SIO
41
h
01
h
C/Q1 PIN SIO Operating
Mode
R/W uint8
00
h
: Transponder Presence
01
h
: Compare Data
02
h
: Alarm 1
03
h
: Alarm 2
04
h
: No SIO
00
h
02
h
SIO Start Address C/Q1 R/W uint8
Transponder memory block address where to
make the “Compare Data” operation
00
h
,
03
h
C/Q1 SIO Data to compare R/W uint32
Reference data value stored in RWM memory to
be compared to transponder data
00
h
, 00
h
,
00
h
, 00
h
04
h
C/Q1 PIN SIO Polarity R/W uint8
00
h
: Output “close” if condition = true
01
h
: Output “open” if condition = true
00
h
05
h
Data Hold Time Output
(C/Q1 & Q2)
R/W uint8
00
h
: No Hold Time
01
h
: Hold Time 100 ms
02
h
: Hold Time 200 ms
03
h
: Hold Time 500 ms
04
h
: Hold Time 1000 ms
05
h
: Hold Time 2000 ms
00
h
06
h
Q2 PIN SIO Operating Mode R/W uint8
00
h
: Transponder Presence
01
h
: Compare Data
02
h
: Alarm 1
03
h
: Alarm 2
04
h
: No SIO
00
h
07
h
SIO Start Address Q2 R/W uint8
Transponder memory block address where to
make the “Compare Data” operation
00
h
08
h
Q2 SIO Data to compare R/W uint32
Reference data value stored in RWM memory to
be compared to transponder data
00
h
, 00
h
,
00
h
, 00
h
09
h
Q2 PIN SIO Polarity R/W uint8
00
h
: Output “close” if condition = true
01
h
: Output “open” if condition = true
00
h
RF CONFIGURATION
42
h
03
h
RSSI
Threshold
R/W uint8
0 = 0
1 = 1
2 = 2
3 = 3
4 = 4
5 = 5
6 = 6
7 = 7
01
h