3.7 General Installation Practices
WARNING: Before attempting to service any pneumatic components, ensure the air
system has been vented to atmosphere (zero pressure in air lines).
CAUTION: Contaminants in the air system can significantly reduce the component life
and performance of the remote control pneumatics. Therefore, to insure long
component life and optimum system performance it is essential to implement a
preventive maintenance schedule for the locomotive pneumatics system. This should
include draining water from the main reservoir tank and replacing filter cartridges.
Failure to maintain main reservoir and/or filter may void the warranty.
3.7.1 General Installation Practices
¾ Resolve any problems with the locomotive’s operation prior to attempting any
remote equipment installation or operation.
¾ All field wiring should be done by a qualified electrician. All electrical work and
practices must meet all federal, state, local, and industry standards.
¾ Route all wire and/or cable to avoid moving parts, mechanical vibration points,
pinch points, and high temperature surfaces. All wiring/cabling should be secured
and must meet all federal, state, local, and industry standards.
¾ Do not run power (high voltage >
50V) together with control (low voltage < 50V)
wire or cable.
¾ Electrical wiring running through the engine compartment should be contained in
conduit of proper rating for the environmental conditions present.
¾ All field plumbing should be done by a qualified technician. All plumbing work and
practices must meet all federal, state, local, and industry standards.
¾ Route all tubing and/or pipe to avoid moving parts, mechanical vibration points,
pinch points, and high temperature surfaces. All tubing/piping should be secured
and must meet all federal, state, local, and industry standards
¾ All plastic plumbing components must be DOT Approved.
¾ All equipment must be shock mounted in an appropriate manner to withstand all
normal operational conditions.
¾ Always read and follow all instructions provided with specific components in the
field installation parts kit.
¾ System specific requirements are included in the system print package. Please
review before beginning the installation. If you have any questions please contact
Control Chief Application Engineering department.