OPERATING INSTRUCTIONS
Normal display shows inside and outside temp in 1/10 degree.
1. One point temp control
a. High Temp Alert “▲
Slide switch to temp “Alert” position, press “Alert Select” to select
High Temp Alert “▲” mode.
Press “Hi Set” to set desired High Temp Alert.
Press “Alert On/Off” to turn on the High Temp Alert. (“Alert” flag appears on
display.)
Alarms and LCD flashes 5 sec every one min when the sensed temp is higher
than the set temp.
b. Low Temp Alert “▼
Slide switch to temp “Alert” position, press “Alert Select” to select Low Temp Alert
“▼” mode.
Press “Lo set” to set desired Low Temp Alert.
Press “Alert On/Off” to turn on the Low Temp Alert. (Alert flag
appears on display.)
Alarms and LCD flashes 5 sec every one mm when the
sensed temp is lower than the set temp.
FITTING THE OUTSIDE SENSOR: LOCATE OUTSIDE SENSOR AWAY FROM
DIRECT SUNLIGHT AND HEAVY SATURATION.
2. Two point temp control
a. Inside Temp Alert “
Slide switch to temp “Alert” position, press “Alert Select” to select
Inside Temp Alert “ ” mode.
Press “Hi set” to set the desired upper temp alert value.
Press “Lo set” to set the desired lower temp alert value.
Press “Alert on/off” to turn, on the Inside Temp Alert. (“Alert” flag appears on
display).
Alarms and LED flashes 5 sec every one mm when the sensed temp is within the
set temp.
b. Outside Temp Alert “
Slide switch to temp “Alert” position, press “Alert select” to
select Outside Temp Alert “ ” mode.
Press “Hi set” to set the desired upper temp alert value.
Press “Lo set” to set the desired lower temp alert value.
Press “Alert on/oft” to turn on the Outside Temp Alert. (“Alert” flag appears on
display)
Alarms and LED flashes 5 sec every one mm when the sensed temp is outside the
set temp.
3. Slide switch to “Temp” position after setting temp alert.
4. Alert off
Press “Alert on/off” in temp “Alert” position, “Alert” flag disappears on display.
BATTERY REPLACEMENT:
1 Pc “AAA” or “UM4” battery
Insert the battery as direction indicated.
Use fingernail to lift up battery cover and insert battery as to indicated direction.
EASY MOUNTING OF BRACKET ON WALL BY:
Double-sided tape or
Screws
WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration, contact:
CONTROL COMPANY
4455 Rex Road
Friendswood, Texas 77546 USA
Ph. 281-482-1714 Fax 281-482-9448
E-mail sales@control3.com
www.control3.com
Control Company is ISO 9001 Quality-
Certified by DNV and ISO 17025 accredited
as a Calibration Laboratory by A2LA.
TRACEABLE
®
BIG-DIGIT 4-ALERT THERMOMETER °C/°F INSTRUCTIONS

Summary of content (1 pages)