Instruction manual

23
Memory Backup
The memory backup will save and protect programs and option settings indefinitely. If a power outage occurs only the
clock setting may be affected. The clock will continue to run, and display on the LCD screen, for up to one to two days
even without power, due to the re-chargeable backup battery inside the unit. However, if the power outage is longer
than two days the clock will be reset (the unit will reset itself to a 9:00 a.m. default).
Thermostat Surface Temperature
In normal operation the surface temperature of the thermostat may range from 45-55ºC (113- 31ºF).
This is perfectly normal, as this thermostat is rated to operate safely at these temperatures.
However it is recommended that the thermostat not be installed near heat sensitive/ammable material such as
exposed wood, wallpaper or other re hazards.
Specifications:
Number of Programs: 5+1+1 Day with four settings per day
Temperature Display Range: 0-55ºC (32-131ºF)
Temperature Setting Range: 5-35ºC (41-95ºF)
Ratings: 120 V/240 V AC, 60 Hz
Maximum Load: (12.5 A)
3000 W @ 240 V or 1500 W @ 120 V
Minimum Load: 500 W @ 240 V