Lighting Design Guide
Table Of Contents
- Legal notices
- Introduction
- A complete control solution
- Comprehensive control options
- Enhanced user interface customization
- Integration simplicity
- Best-in-class dealer tools and support
- Wireless Lighting components
- Panelized Lighting components
- System design types
- Specifying a system
- Control4 Wireless Adaptive Phase Dimmer
- Control4 Wireless Keypad Dimmer
- Control4 Forward Phase Dimmer
- Control4 Wireless Switch
- Control4 Wireless Configurable Keypad
- Control4 Wireless Fan Speed Controller
- Control4 Wireless 0-10V Dimmer
- Control4 Auxiliary Keypad
- Control4 Wireless Outlet Dimmer and Switch
- Third-party products
- Control4 5-Slot and 2-Slot Panels
- Control4 8-Channel 0-10V Dimmer
- Control4 8-Channel Dimmer
- Control4 8-Channel Relay
- Control4 8-Port Ethernet Switch
- Control4 Bus Ethernet Gateway
- Control4 Bus Power Supply (48V)
- Control4 Decora Wired Keypad
- Control4 Square Wired Keypad
- Control4 Terminal Blocks
- Control4 4-Channel Bus Dry Contact Input Module
- Lighting project checklist
- Wireless Lighting application
- Panelized Lighting application
13
Specifying a system
Electrical panel schedule
Electrical panel schedule
Details from the electrical floor plan are used by the electrical
engineer to create the panel schedule(s). This important source
of information provides details regarding every electrical load
and how it is connected to a panel board circuit. The schedule
provides key information, such as:
• Load description
• Voltage and current requirements
• Circuit breaker numbers (or addresses)
• ARC-FAULT requirements
• Wire/Conductor size
Light fixture schedule
The light fixture schedule can contain the following information:
• Dimmable vs. switchable loads
• Dimming level requirements
• 0-10V dimming requirements
• Location of low-voltage lighting transformers or driver
circuitry*
• Color (RGB) lighting control requirements
• Plug load control locations*
* This item should be shown on the plans for location, but could
be described on the light fixture schedule.
Light fixture schedule
SPMALERUTXIFERUTXIFERUTXIF
GNITNUOMSTTAWSTLOV.YTQEPYT# GOLATACRERUTCAFUNAMREBMUN
A
METALUX
DAYBRITE
2GC8-332A125-EB81
2DPG332-FS12-1/3EB
2X4 PRISMATIC LAYIN FIXTURE
SPECIFICATION GRADE (3-LAMP)
F32T8/SP35
ECO
3 120 99
LAY-IN
GRID
B
METALUX
DAYBRITE
2GC8-332A125-EB81
2DPG332-FS12-1/3EB
2X4 PRISMATIC LAYIN FIXTURE
SPECIFICATION GRADE (3-LAMP)
F32T8/SP35
ECO
3 120 99
LAY-IN
GRID
C IRIS P3LED09-NFL25-927-E010
RECESSED 3.5" APERTURE
DOWNLIGHT LUMINAIRE
900 LED 1 120-277 14.7 RECESSED 0-10V 10% DIMMING
D
CREE
OMEGA
LR6C-H6-LT6A-DIR
-
LED DOWNLIGHT W/ANODIZED TRIM
650 LUMENS
650L LED 1 120 12 RECESSED 3-WIRE AND ECOSYSTEM 1% DIMMING, LUTRON A SERIES
A/N#A/N#A/N#A/N#A/N#A/N#A/N#A/N#E
A/N#A/N#A/N#A/N#A/N#A/N#A/N#A/N#F
A/N#A/N#A/N#A/N#A/N#A/N#A/N#A/N#G
NOTE:
ELECTRICAL CONTRACTOR SHALL PROVIDE A 'QUICK DISCONNECT HARNESS' FOR EACH FLUORESCENT LIGHTING FIXTURE TO SERVE AS A MEANS OF
DISCONNECT TO ALLOW THE FIXTURE BALLAST TO BE SERVICED IN PLACE, AS PER THE NATIONAL ELECTRICAL CODE 2008, ARTICLE 410.130 (G).
REMARKS
FIXTURE
LIGHT FIXTURE SCHEDULE
DESCRIPTION