Control4 Wireless Switch
Control4 Wireless Switch
120V/277V (C4-SW120277), 240V (C4-SW240)
The Control4® Wireless Switch provides on/o control for a
variety of load types, including:
Incandescents
Halogens
Electronic low-voltage (solid state) transformers
Magnetic (iron core) low-voltage transformers
Fluorescents
Compact fluorescents
LEDs
Motors
Product features
Provides on/o control of non-dimmable loads.
With its durable relay and high amperage rating, it can handle
high in-rush loads such as fountain pumps, large banks of
fluorescent lights, and wall outlets.
Available in a wide array of gloss and satin colors (see
Available Colors in the specifications table).
Custom engraving available to clearly identify which load each
switch controls.
Backlit engraving provides easy readability regardless of light
level or time of day.
Status and backlight LED colors can be set to reflect a device
or scene status or simply to complement the room’s décor.
Ambient light sensor automatically adjusts backlight and
status LED brightness, depending on the light level in the
room.
Can be repurposed in Composer to act as a 2-button keypad
with no direct load control.
Continuously monitors energy consumption of the connected
load.
Air gap actuator on the top of the switch disconnects power
to the device.
Included
Switch
Wire nuts (120V/277V) or Terminal Block (240V)
Switch Installation Guide
Installation notes
Follow all instructions in the installation guide.
This device must be installed by a licensed electrician.
Installs in a standard NEMA wall box using typical wiring
standards.
When used in conjunction with an Auxiliary Keypad
(C4-KA-xx), the wire connecting the Auxiliary Keypad to this
device must not exceed 150 feet (45 meters) at 120VAC and
100 feet (30 meters) at 277VAC.
Requires a neutral connection and an earth ground
connection.
Full load control is available from the device before being
identified into a project.
Grounding is highly recommended for this product. Grounding
will protect the device from ESD (electrostatic discharge)
eects. Follow the wiring diagrams in the installation guide.
WARNING! This device must be protected by a circuit breaker
(20A max).
For full installation instructions and warnings, see the Switch
Installation Guide. See Control4 training materials for best
practices on ZigBee installation.
Remember faceplates! (Not included)
Gloss: White (WH), Light Almond(LA),
Ivory(IV), Brown(BN), Black(BL)
Satin: Snow White (SW), Midnight
Black(MB), Biscuit(BI), Aluminum(AU)
Metal: Satin Nickel (SN), Stainless
Steel(SS), Venetian Bronze(VB)
1-Gang (C4-FP1-xx), 2-Gang (C4-FP2-xx),
3-Gang (C4-FP3-xx), 4-Gang (C4-FP4-
xx), 1-Gang Square (C4-SFP1-xx)