Lighting Design Guide

Table Of Contents
48
Control4 5-Slot and 2-Slot Panels
Control4 5-Slot and 2-Slot Panels
5-Slot Panel (C4-DIN-5PAN), 2-Slot Panel (C4-DIN-2PAN)
The Control4® 5-Slot and 2-Slot Panels house all centralized
components of a Control4® Panelized Lighting system. Both
panels include a variety of creative features designed to make
installation and wiring of the system quick and convenient.
Product features
Surface mount or flush mount between a standard 16-inch-on-
center stud bay.
Generous space at the top and bottom of the panel for
electrical wiring, along with numerous knock-outs at top,
bottom, and sides.
Swivel divider at the top and bottom eectively separates
line-voltage and low-voltage wiring, providing the maximum
amount of space possible for each type of wire as needed.
Several zip-tie points on the left and right of the panel for wire
management.
DIN rail mounting for modules allows modules to easily snap
on and o—no screws required.
Terminal block mounting points provide quick and easy
installation of terminal blocks (sold separately).
All modules protrude through the front cover for access to
channel status LEDs and easy control of individual loads
without having to remove the cover (optional security cover
available to prevent access to module buttons and LEDs if
desired).
Specifications
Control4® 5-Slot Panel Control4® 2-Slot Panel
Model number C4-DIN-5PAN C4-DIN-2PAN
Back Box Dimensions (H×W×D) 63.9" × 14.3" × 3.8" (162.3 cm × 36.2 cm × 9.5 cm) 33.5" × 14.3" × 3.8" (85.1 cm × 36.2 cm × 9.5 cm)
Dimensions with Cover (H×W×D) 65.5" × 16" × 0.3" (166.37 cm × 40.64 cm × 0.6 cm) 34.9" × 16" × 0.3" (88.6 cm × 40.64 cm × 0.6 cm)
Weight 49.4 lb (22.4 kg) 27.35 lb (12.4 kg)
Shipping Weight 56.5 lb (25.6 kg) 33.6 lb (15.2 kg)
Included
Front cover (metal)
Back box (metal)
C4-DIN-SF Slot Fillers
5-Slot Panel (2 packages)
2-Slot Panel (1 package)
5-Slot and 2-Slot Panels Installation Guide
Installation notes
Panels must be installed vertically.
The panels are convection cooled. Install the panel in a
location where the vented cover is not blocked. At least 12
inches (30 cm) clearance is required away from the front of
the panel. Some local codes may require as much as 36 inches
(91 cm) of clearance.
Install the panel in a climate-controlled area to prevent module
overheating.
Install the panel where some noise is acceptable. Modules in
the panel may hum and make clicking noises when in use.
Panels may all be centrally located or may be distributed
throughout the home or business.
Panels should be installed prior to rough-in wiring, allowing
the electrician to pull cables directly into the panel during the
rough-in.
For full installation instructions and warnings, see the 5-Slot and