Specification Sheet

Control4® Wireless Adaptive Phase Dimmer
Model numbers C4-APD120, C4-APD240, C4-APD277
Power requirements
C4-APD120: 120VAC +/-10%, 50/60 Hz
C4-APD240: 220VAC-240VAC +/-10%, 50/60 Hz
C4-APD277: 277VAC +/-10%, 50/60 Hz
This device can function with or without a neutral AC connection
depending on load type.
Power consumption
C4-APD120: 714mW
C4-APD240: 1.94W
C4-APD277: 2.44W
Load types and ratings
Supported load types
Incandescent, halogen; electronic (solid state) low-voltage (ELV)
transformers, magnetic (iron core, inductive) low-voltage (MLV)
transformers
1
, phase-dimmable fluorescents, compact fluorescents, and
LEDs.
C4-APD120 maximum load
1 Gang 2 Gang 3+ Gang
Incandescent (tungsten) 600W 550W 500W
Halogen
1
600W 550W 500W
Fluorescent
2
300W 300W 300W
Compact fluorescent (CFL)
2
300W 300W 300W
LED
1,2
120W 120W 120W
C4-APD240 reverse phase maximum load
1 Gang 2 Gang 3+ Gang
Incandescent (tungsten) 800W 700W 600W
Halogen
1
800W 700W 600W
Fluorescent
2
500W 500W 500W
Compact fluorescent (CFL)
2
500W 500W 500W
LED
1,2
160W 160W 160W
C4-APD240 forward phase maximum load
1 Gang 2 Gang 3+ Gang
Incandescent (tungsten) 400W 400W 400W
Halogen
1
400W 400W 400W
Fluorescent
2
400W 400W 400W
Compact fluorescent (CFL)
2
400W 400W 400W
LED
1,2
160W 160W 160W
C4-APD277 maximum load
1 Gang 2 Gang 3+ Gang
Incandescent (tungsten) 1000W
900W 800W
Halogen
1
1000W 900W 800W
Fluorescent
2
500W 500W 500W
Compact fluorescent (CFL)
2
500W 500W 500W
LED
1,2
200W 200W 200W
Minimum load (with neutral), all models
C4-APD120 C4-APD120 C4-APD120
All load types
1,2
1.2W 2.4W 2.8W
Minimum load (without neutral)
Incandescent (tungsten) 7W
Halogen
2
7W
Fluorescent
1,2
Not recommended
Compact fluorescent (CFL)
1,2
Not recommended
LED
1,2
Not recommended
NOTES:
1
When dimming magnetic (MLV) loads, each transformer must be loaded to at least 50% of its maximum load
2
The minimum and maximum load requirements for fluorescent, CFL, and LED loads can vary greatly depending on the
specific fixture and/or bulb being used. The quality and performance of these load types vary greatly from manufacturer
to manufacturer.