Factory Default Settings
Default Step Maximum
--3 min (approx.)Courtesy light time
11 12Obstruction force margin
--30 secAuto-close time
Technical Specifi cations
230-240V AC, 50HzMains
2.2 WattsStandby power
240 WattsRated input power
24V DC Permanent Magnetepyt rotoM
14.9m (5500mm (Width) x 2700mm (Height))Maximum door size
550N (55kg)Short-term peak force
400N (40kg) Rated lifting force
No greater than 150N (15kg)
Recommended force for manual operation
(excessive forcee)
4 minRated Operating Time
3.0 turns of Door Durm WheelOpener Limits Travel
14 x 4 button Transmitter Codes Receiver code storage capacity
UHF Multi-frequency FMTransmitter/Receiver type
Multi-frequency Code HoppingCoding type
Over 4.29 billion random codesNumber of code combinations
NOTE:
1. The door must be well balanced. A person should be able to lift the door up manually with very little effort in
case of an emergency.
2. Intermittent operations may occur in areas which experience very strong winds. Strong wind puts extra pressure
on the door and tracks which may in turn trigger the safety obstruction detection system intermittently.
Default Settings & Specifications
Non-linear encryption algorithmCode generation
2
Maximum door weight
CR2032 (3V)Transmitter battery
L.E.D. (Light Emitting Diodes), 2 modulesCourtesy light
210 kg
10A slow blowController fuse