Instruction manual

Pre-Installation Requirements
WARNING! Incorrect installation can
lead to severe injury - FOLLOW ALL
INSTALLATION INSTRUCTIONS.
Door Operation
The door must be in good operating condition. The
maximum effort to move the door up or down, from
stationary, should not exceed 200 Newtons (20kg force) at
the bottom rail. The recommended force is 70N (7kg) for
manual operation.
Lift the door to about halfway. When released, the door should
stay in place supported entirely by its springs. Also raise and
lower the door to check for any binding or sticking.
The door may need to be serviced to meet these
requirements – refer to the door manufacturer’s servicing
instructions or contact an authorised dealer.
Unsuitable Door Types
The fi tting of an opener to doors with removable mullions is
not recommended.
IMPORTANT NOTE - The opener should
not be installed on any door incorporating a
wicket door.
Position
The opener can be installed on either the right hand or left
hand side of the door (when viewed from inside the garage).
The opener is factory set for right hand side installation.
This opener must be installed in a dry position that is
protected from the weather. Moisture or corrosion damage
is not covered by the Warranty.
Power Supply
A properly earthed 3 pin single-phase power supply is
required.
WARNING! A portable power generator is
not recommended. The opener may appear
to malfunction due to spikes, surges and
fl uctuations in the generated voltage.
Side room
The minimum side room required from the edge of the
door curtain is 41mm to the inside of the door bracket, and
85mm to the wall (Fig. 01).
The recommended side room from the edge of the door
curtain is 95mm to the inside of the door bracket, and
135mm to the wall (Fig. 02).
NOTE: Door Axle Diameter must not exceed 35mm.
Fig.01
Fig.02
Controll-A-Door
®
Diamond PD - Power Drive Instruction Manual8