Instruction manual

Default Settings & Speci cations
Factory default settings
Default Step Minimum Maximum
Maximum opener run time 60 seconds - - -
Courtesy light time 4 minutes (approx.) - - -
Obstruction force margin 2 1 0 14
Auto-Close time 30 seconds - - -
Technical speci cations
Power supply 230V - 240Va.c. 50Hz
Transformer rating 24Vd.c.
Standby power 2.2 Watts
Motor power 100 Watts
Motor type 24Vd.c. permanent magnet
Shuttle travel distance in the C-Rail 2.7m approx. (standard)
Maximum shuttle travel distance in the C-Rail 3.750 m (with one extension)
Maximum door opening: Width:
Height:
Weight:
5500mm (16.5m
2
)
3000mm
100kg
Minimum headroom 30mm
Short term peak force 1000N (100kg) with Chain
800N (80kg) with Timing Belt
Lift force 600N (60kg) with Chain
500N (50kg) with Timing Belt
Nominal force 150N (15kg)
Receiver type UHF Multi-frequency FM Receiver
Receiver code storage capacity 14 X 4 button Transmitter Codes
Transmitter frequency UHF Multi-frequency FM Transmitter
Coding type Code Hopping
Number of code combinations Over 4.29 billion random codes
Code generation Non-linear encryption algorithm
Transmitter battery CR2032 (3 Volts)
Courtesy light LED (Light Emitting Diodes)
Controller fuse 10A slow blow
*The actual travel of the door depends on con guration of the connecting arms.
Note: Intermittent operations may occur in areas which experience very strong winds. The strong wind puts extra pressure
on the door and tracks which may in turn intermittently trigger the safety obstruction detection system.