Instruction manual
Default Settings & Specifications
Factory default settings
Default Step Minimum Maximum
Maximum motor run time 40 seconds - - -
Courtesy light time 4 minutes
(approx.)
- - -
Obstruction force margin 2 1 0 24
Auto-Close time 30 seconds - - -
Technical specifications
Power supply 230V - 240Va.c. 50Hz
Transformer rating 24Va.c.
Standby power 2.0 Watts
Motor power 250 Watts (1/3 HP)
Motor type Alternating Current
Maximum door opening: Width:
Height:
Area
Weight:
5500mm
3000mm
16.5m
2
100kg
Minimum headroom
50mm
Short term peak force 800N (80kg)
Lift force 600N (60kg)
Nominal force 150N (15kg)
Receiver type UHF Multi-frequency FM Receiver
Receiver code storage capacity 14 X 4 button Transmitter Modes
Transmitter frequency UHF Multi-frequency FM Transmitter
Coding type Code hopping
Number of code combinations Over 4.29 billion random codes
Code generation Non-linear encryption algorithm
Transmitter battery CR2032 (3 Volts)
Courtesy light LED (Light Emitting Diodes)
Controller fuse 5A slow blow
Rated temperature +5º to 40º
Note: Intermittent operations may occur in areas which experience very strong winds. The strong wind puts extra pressure
on the door and tracks which may in turn intermittently trigger the safety obstruction detection system.
Controll-A-Door
®
P Instruction Manual4