Instruction manual
2 flash
1 flash
2 flash
2 flash
Controll-A-Door
™
AUTOMATIC GARAGE DOOR OPENER
POWER
CODE SET
LIMIT SET
WARNING: Cover not to be removed except by
authorised technician
Controll-A-Door
™
AUTOMATIC GARAGE DOOR OPENER
POWER
CODE SET
LIMIT SET
WARNING: Cover not to be removed except by
authorised technician
2 flash
3 flash
Controll-A-Door
™
AUTOMATIC GARAGE DOOR OPENER
POWER
CODE SET
LIMIT SET
WARNING: Cover not to be removed except by
authorised technician
2 flash
4 flash
Controll-A-Door
™
AUTOMATIC GARAGE DOOR OPENER
POWER
CODE SET
LIMIT SET
WARNING: Cover not to be removed except by
authorised technician
3 flash
1 flash
Controll-A-Door
™
AUTOMATIC GARAGE DOOR OPENER
POWER
CODE SET
LIMIT SET
WARNING: Cover not to be removed except by
authorised technician
Stays on
Controll-A-Door
™
AUTOMATIC GARAGE DOOR OPENER
POWER
CODE SET
LIMIT SET
WARNING: Cover not to be removed except by
authorised technician
Check the wiring to the Safety Infra Red
Beams. If there are no shorts then the IR
Beam detectors may need servicing.
Either the operate button in the light cover
is stuck or an external operate button is
shorted. Remove the light cover - check the
operate button is not stuck or remove the
accessory plug to identify fault.
Either the Limit Set button is stuck or an
external limit set button is shorted. Remove
the light cover and remove the accessory
plug, if fault remains contact B&D or an
authorized dealer for service.
The Code Set button may be stuck down.
Try pressing the button or reset the opener.
If problem persists contact B&D or an
authorized dealer for service
An internal electronic fault has occurred.
Call B&D or an authorized dealer for service
The Code Set LED will illuminate whenever a
433MHz signal is being transmitted. If the Code
Set LED stays on it indicates that there is possibly
a 433MHz remote control transmitter with a button
stuck on. To identify the faulty remote control
transmitter, remove the battery from each
transmitter checking the Code Set LED each time.
When the battery is removed from the faulty
transmitter the Code Set LED will go out.
©Copyright 2001
B&D Australia
Page 19
Diagnostic Code Action
2-1
2-2
2-3
2-4
3-1
While the opener is flashing an error code it will not respond to a remote control signal, nor can it learn codes
or limits.
The opener can be reset from error mode by either:
• interrupting the mains power,
• by pressing the operate button, or
• by pressing a remote control transmitter that has previously been coded into the opener.