Instruction manual
SECTION 1 - REQUIREMENTS
IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION
WARNING - INCORRECT INSTALLATION CAN LEAD TO SEVERE INJURY.
FOLLOW ALL INSTALLATION INSTRUCTIONS.
DOOR OPERATION
The door must be in good operating condition and the maximum effort to move the door up or down, from stationary,
should not exceed 200 Newton’s (20kg force) at the bottom rail. The door may need to be serviced to meet this
requirement - refer to door manufacturers servicing instructions
Before installing the opener, check that the door is in good mechanical condition and correctly
balanced and that it opens and closes properly. AS3350
Note: The fitting of an opener to doors with removable mullions is not recommended.
POSITION
It is recommended that the opener be installed on the right hand side of the door, however the opener can be
installed on either the right hand or left hand side of the door (viewed from inside the garage looking out - left is left).
The opener must be mounted in a dry position that is protected from the weather. The B&D Controll-A-Door 5
®
is not
designed for external use. Moisture or corrosion may damage the opener and this is not covered by the Warranty. Do
not allow water, or other liquids, to enter the opener or remote control transmitter.
POWER SUPPLY
A properly earthed, 3 pin, 240 volt power supply is required.
WARNING! A portable power generator is not recommended. The opener may appear
to malfunction due to spikes, surges and fluctuations in the generated voltage.
SIDEROOM
Dimension A = 75mm maximum. This is the distance from the door drum to the
edge of the door curtain/door guide. If dimension A is greater than 75mm, a ring gear
adaptor (Part No 59585) will be required.
Dimension B = 120mm minimum to 135mm maximum. This is the distance from
the door drum to the inside of the door bracket.
Dimension C = 165mm minimum. This is the distance from the door drum to the
garage wall.
Note:
1 The door bracket may have to be relocated to line up with the slots in the mounting bracket of the opener (the
opener may be mounted onto the axle - see Fit The Opener for special instructions.
2 The chassis must not
be cut down to reduce sideroom - the warranty is invalidated if this occurs.
3 These dimensions assume the opener will be fitted while the door is on the floor. If the door is already installed an
additional 150mm clearance is required to slide the opener over the axle.
Page 6 ©Copyright 2001
B&D Australia
AS3350