Instruction manual

RED
BLACK
RED
BLACK
RED
BLACK
YELLOW
R1=2.2K OHM
RED,RED,RED,GOLD
.25WATT 5% TOLERENCE
RESISTANCE
R1
YELLOW
BLACK
V- IN V+
P.E BEAM
IMPORTANT NOTE - The Safety Infra-red
Beam must be installed and connected before
the travel limits are set - See Step 12.
WARNING: Doors requiring over 400N of force
to move must have Saftey Infra-red Beams tted
for safety.
Step 18 - Safety Infra-red Beam
Safety Infra-red Beam extends across the door opening. This
Safety Infra-red Beam is designed to detect an obstruction
while the door is closing and to send a signal to the door
opener to reverse or stop the door movement.
Step 18.1 - Fitting Safety Infra-red Beam
Attach the mounting bracket (4) to adjustment bracket
(3) with the pan head screw (6) (supplied) (Fig. 36).
Attach the PE 2000TS bracket (2) to Safety Infra-
red Beam transmitter (IR-200TS-TX) with four taptite
screws (m3x5) and attach the other side to adjustment
bracket (3) with the pan head screw (6) (supplied).
Repeat steps a and b to assemble the Safety Infra-red
Beam ( IR-200TS-RX).
Locate the Safety Infra-red Beam in a strategic location
in the gateway. B&D recommend that the sensor is
placed 150 mm above the oor level. Connect as per
the wiring diagram (Fig. 38).
Use 2.2 kilo ohm resistor with the colour code red, red,
red and gold on the Safety Infra-red Beams receiver
between the V- and NC terminals as shown in (Fig.
38).
Step 18.2 - Alignment
Power up the Safety Infra-red Beam. The green LED on
the transmitter and red LED on the receiver should turn
ON to indicate power is present.
If the receiver is connected to power and the red LED
is on while the green LED is on, the transmitter and
receiver are not aligned.
Make horizontal and/or vertical (Fig. 37) adjustment
on the transmitter and/or receiver until the red LED
turns off on the receiver, indicating alignment.
WARNING: When using Safety Infra-red Beam,
the doorway must be clear of all obstructions
and persons at all times. The location of the
beams and manner in which it is installed
might not give safety protection at all times.
Check to make sure that the height of the
beam and type used give maximum protection
possible.
WARNING: Install the Safety Infra-red Beam
as per diagram in Fig. 38. Tampering with the
Safety Infra-red Beam could result in serious
personal injury and/or property damage and
will void the warranty.
a.
b.
c.
a.
b.
a.
b.
c.
R1
1
2
3
4
6
5
Fig. 36
Fig. 37
Fig. 38
Accessories
Controll-A-Door
®
S
Instruction Manual20